摘要:The precise formulas for calculating thickness of X-ray balanced filters made from metal foils or oxide-plastic films are deduced from the principle. The fabricating methods of balanced filters and their fluorescence effects are briefly described.
摘要:A composite element filter of absorption edge type described here can be used when the X-ray energy of the wanted element is higher then that of the interference element. It's mainly used in immersion probes. When measuring copper in copper concentrate, the absolute error of the grade achieved is mostly less than ±0.3% and this can fully meet the demand of industrial process control analysis. It can be anticipated that in other pulp on-stream analysis, a relative composite element filter can certainly be made if the content of the neighboring element is high enough and the X-ray energy of the element to be measured is higher than that of the interference element.Preparation of Ni-Cr composite powder, the blending ratio test of the two element, the mass thickness test at the given blending ratio, the modulation and testing of the filter performance and test measurement on the sample of natural powder are given.
摘要:The improvement of the original 1.2m cyclotron to enhance its accelerated particles energies with increasing main magnet exciting current and reshimming the magnetic field is described. After the improvement, the energy of deutron particles was enhanced from 13.6MeV to 16MeV, and the energy of α particles to 32MeV.
摘要:The scanning instrument used in electron irradiation is an important device of the electron accelerator. In order to improve the homogeneity of the radiation dosage, it is proposed that the homogeneity of the scanning can be raised if the scanning magnetic field is produced by the electric current composed of both the trigonometric and sine waves.
摘要:Three kinds of ionization chamber for X-ray and γ-ray dosimetry are here described: a) Ionization chamber of 0.5cm3 with pure graphite wall and alumunium collecting electrode. In case of radiation having a HVL between 0.07mm Cu to 2.5mm Cu corresponding to a X-ray tube voltage of about 60 to 220kV, the maximun error of the energy response was below 1.5%. The calibration factor of 137Cs and 60Со γ radiation also fell in with above range when an additional 3.75mm thick lucite build-up cap was fitted. b) Ionization chamber of 2cm3 with bakelite, pure graphite or teflon wall the maximun error of energy respose was lied between 3~5%; c) Ionization chamber of 200 cm3 with bakelite plastic wall,the maximun error of energy response was below 5%. All of them can be used as secondary standard Röntgen meter and in protection dose measurement.
摘要:This paper describes the principle and application of correlation method in the absolute radioactivity measurement. This new method measures the quantity of charge occurring in the detectors instead of the number of voltage pulse and then calculats the correlative quantity of the charge between two channels. Finally it gives the absolute activity of the measured sample. The purpose of this method was to make an attempt to decrease some trouble raised from dead time correction.
摘要:A simple method for absolute assay of medical solution of 125I is described, which takes advantage of the area in the coincident sum peak in the single crystal NaI (Tl) γ-ray spectrum. Using this method to various measurement conditions, we get accuracy within 1%.
摘要:Metabolism of 35S-patan was studied by means of macro-autoradiography and homogeneous liquid scintillation counting. The dynamic distribution of radioactivity in the body showed that this drug was absorbed rapidly and its accumulation decreasing with the order of kidney, liver duodenum, lung and trace in brain. This radioactive drug was eliminated rapidly with about 89.11% of the administered radioactivity in 48 hours after injection. 35S-patan was chiefly excreted in the urine and kept unchanged in form.
摘要:With the principle of component combination isolation being applied the power source is inclosed in a earthed metallic enclosure (volume: 10×20×34 cm3, weight: 14.3 kg) and powered directly by a power supply with commercial frequency of 50 Hz. The output voltage can be adjusted continuously from 0~120kV by means of a small adjustable autotransformer. The output lead is a 150kV cable with maximum output power being 100W. The complete set can be carried in a hand bag, working safely and operated easily.
摘要:An ionization chamber used in an ore-pulp-density gauge is presented. Its stability, sensitivity, plateau characteristic and the measures adopted in construction are briefly described.
摘要:In this work, the average perturbed angular correlation integral attenuation factor G2 were measured using time—integral perturbed angular correlation method, 0.1205 ± 0.0098 for serum of cancer LCR rats, 0.1853±0.0324 for normal LCR rats. The difference between these two factors is obvious (P<0.01) . Because the 111In is bound to transferrin molecule in the serum, it seems that the equivalent radius of transferrin molecule of cancer LCR rats is smaller than that of normal LCR rats and the molecular conformations are different with each other.