摘要:A method, based on servo-compensation principle, for the modulation of nuclear rays or X-ray and frequency selective amplification has been analysed and evaluated. It turns out that the adoption of this method could result in the elimination of effects due to many unfavorable factors, such as: the environmental variation of temperatures pressure and humidity; the ageing of electronic devices; the fluctuation of power supply. Therefore, this method is very beneficial to the construction of various type, of high accuracy radioisotope instruments.
Nuclear Geophysic Research Laboratory, Chengdu College of Geology
1981, 04(3)
摘要:A portable radioisotope X-ray fluorescence analyser and an X-ray fluorescence logger have been designed and manufactured with the following characteristics: (1)Low power consumption due to the adoption of state-of-the- art GOS/MOS circuiting; (2) Small size and light weight, hence portable and applicable in the field; (3) Excellent stability in performance and reliability.Such analyser and logger have already found effective use in many kinds of ore deposits such as copper, iron, chromium, molybdenum, uranium and tin.
摘要:Two methods and associate apparatus for rapidly on line measuring the silve content in photographic film emulsion by means of radioisotope source excited X-ray fluorescence are described. Following results are obtained with the first method: 1g/m2 silver content equals to 24 cps, analysis period is 200 seconds and relative error ±5%. The detector can be used with a universal radioisotope source X-ray fluorescence analyzer.In another method, the equivalent of 1g/m2 silver content is 1000cps, analysis period 10 seconds and relative error ±5% (95% confidence level) in the range of 1 ~8g/m2 silver content. According to this method, a silver gauge has well been designed and manufactured.Both these two methods are suitable for the application of determinating the silver content in coating process on line or in a routine test.
Dai Teng-chang,Hu Ya-er,Xia Zong-qin,Ding Xiu-juan,Ju Jiu-hong
1981, 04(3)
摘要:A modified method of cGMP RIA is presented in this paper. Succinylation of cGMP was catalyzed by triethylamine in an aqueous medium and the 2'-o-ScGMP thus formed was conjugated with BSA or thyroglobulin under the action of EDCI. The ScGMP-BSA or ScGMP-TG obtained was used as an antigen to induce antibody in rabbits. 3H-cGMP (15 Ci/mmol) was used as the labelled ligand. Both labelled and unlabelled cGMP were acetylated with acetic anhydride and triethylamine prior to the addition of antiserum. Ka was estimated to be 2×109M-1; the final dilution of antiserum was 1:3000; the sensitivity of the calibration curve was 0.03 pmol; and the cross reaction with cAMP was 1:500. Treatment of plasma samples was improved by adding 1/10 volume of 3.3% acetic acid in ethanol and heating at 70℃ for 4 minutes to precipitate proteins. 100µl of the supernatant was used directly in each tube for immunoassay reaction. The procedure was thus simplified, since there involved almost no dilution of plasma. The within-assay variance and between-assay variance were 8.0% and 7.2% respectively. The cGMP content of normal plasma was found to be 4.75±0.32 pmol/ml (n=21) , which was very close to the values reported in recent literatures.
摘要:A simple highly sensitive method for monitoring total tritium in air is described. The air was first passed through an ethylene glycole bubbler to remove HTO, then, over a heated catalyst for oxidizing HT gas to HTO which was cellected in second ethylene glycol bubbler. Tritium was measured by liquid scintillation counter. The interference of absorption efficiency and recovery by sampling rate, relative humidity (R. H.) , sampling time (absorbed volume) and tritium concentration in air were studied. The conversion efficiency of HT on oxidized catalyst has been measured. This method can be applied to monitor of tritium laboratory, measurement of tritium leaking rates from tritium reservoir and survey of environment monitoring etc.
摘要:Exposure of wild silkworm eggs to γ-ray from 137Cs or 60Co, in low dose was found to have remarkable effect as that of neutron from Ra-Be source conventionally used to increase production.Neutron from Am-Be source was also found to have such effect.By analyzing the dose contribution of neutron and γ-ray from these two neutron sources, it was that both neutron and γ-rау could produce effect on increasing production.
摘要:We succeeded in making a ring-shaped target of tritium-titanium. The diameter of the ring is 150mm, the thickness of titanium layer is 1mg/cm2, the amount of absorbed tritium is 50 Curies, and the tritium to titanium atom ratio is about 1.3~1.4. With it as a target we perfomed a test at the SINR neutron-generator and bombarded the target with 200keV deuterium. The neutron yield reached 1011n/sec at first and then was decreased 3% after fifteen minutes.
摘要:The scanner equipped with scintillator is used for thin-layer or paper radiochromatogram scanning of ordinaty nuclides emitting γ and β rays, and also for β nuclides of lower energy, e. g. 14C and 35S. The accuracy of displacement of uniform motion is better than 100±1mm. Its performance and data give-out is comparable with that of similar type imported instruments.This instrument can be used in quality control of radioisotope and labelled compound production, and in radiochemical, radiomedical, and radiobiological study.
摘要:The structure of a radiochromatogram scanning equipment for tritium labelled compounds is described. Its efficiency (2~3%) , sensitivity (0.1μCi) and localization resolving power (5mm) are evaluated. It is compared with liquid scintillation counter.
Group of Ge (Li) Detector, Institute of Nuclear Energy Technology, Qinghua University
1981, 04(3)
摘要:In this paper the fabrication technique of a single-ended coaxial Ge (Li) detector is described. The active volume of the detector is about 35cm3. The leakage current at 2500V bias is 4×10-11A. An energy resolution of 2.47 keV (FWHM) for 60Co (1.332 MeV) has been obtained.The technique of etch of surface without protection and the method of clean-up drift in the cryostat are discussed in detail.