浏览全部资源
扫码关注微信
1.中国科学院上海应用物理研究所 嘉定园区 上海 201800
2.中国科学院大学 北京 100049
[ "高波, 男, 1990年出生, 2013年毕业于江南大学, 现为博士研究生, 从事加速器束流诊断相关研究", "GAO Bo, male, born in 1990, graduated from Jiangnan University in 2013, doctoral student, focusing on beam instrumentation" ]
冷用斌, E-mail:leng@sinap.ac.cn LENG Yongbin, E-mail:leng@sinap.ac.cn
收稿日期:2018-04-10,
修回日期:2018-05-04,
纸质出版日期:2018-08
移动端阅览
高波, 冷用斌, 陈汉骄, 等. 同步光空间干涉仪缝距快速扫描系统[J]. 核技术, 2018,41(8):080101
Bo GAO, Yongbin LENG, Hanjiao CHEN, et al. Slit separation rapid scanning system for synchrotron radiation interferometer[J]. Nuclear techniques, 2018, 41(8): 080101
高波, 冷用斌, 陈汉骄, 等. 同步光空间干涉仪缝距快速扫描系统[J]. 核技术, 2018,41(8):080101 DOI: 10.11889/j.0253-3219.2018.hjs.41.080101.
Bo GAO, Yongbin LENG, Hanjiao CHEN, et al. Slit separation rapid scanning system for synchrotron radiation interferometer[J]. Nuclear techniques, 2018, 41(8): 080101 DOI: 10.11889/j.0253-3219.2018.hjs.41.080101.
同步光空间干涉仪技术被广泛应用于国内外各大同步辐射光源的束流横向截面尺寸测量中。在日常使用中空间干涉仪通常采用固定狭缝间距的双缝,测定单一空间频率下的相干度,这种方法在束斑尺寸变化不大的情况下精度较好,分辨率会随束斑尺寸的变化而变化。随着下一代同步辐射光源的发展,精细的束斑尺寸测量需求也越来越迫切,多频点相干度测量精度较高,但是受限于双缝切换的速度。上海光源围绕如何完成快速多频点相干度的测量进行了相关研究,搭建了一套空间干涉仪狭缝间距快速扫描系统。该系统采用双单缝的方式进行缝距快速扫描,并结合多线程的技术实现了快速数据处理。实验结果表明:一次完整的10点测量时间约在3s,大大提升了多频点相干度测量方法的速度,并且提升了现有固定狭缝间距干涉仪的测量精度。
Background
2
Spatial interferometer technology is widely used to measure the transverse beam size of synchrotron radiation around the world. The interferometer usually uses double-slit with fixed slit separation. However
this method is only suitable for measurements with relatively small changes in beam size. With the development of the diffraction limited storage ring
the demand for high-precision measurement is becoming more and more urgent. Multi-frequency coherence measurement can overcome these limitations
but it is limited by the changing speed of double-slit.
Purpose
2
This study aims to improve the speed of multi-frequency coherence measurement by establishment of a slit separation rapid scanning system at Shanghai synchrotron radiation facility (SSRF).
Methods
2
Superimposed double single-slit is employed as the new double-slit mask in this system
and multi-thread technology is used to do fast data processing.
Results
2
The experimental results show that the time for one complete 10 points measurement is less than 3s with better accuracy compared with the traditional interferometer.
[Conclusion]
The new system greatly improves the speed of the multi-frequency coherence measurement and outperform the existing interferometer in terms of accuracy.
Conclusion
2
The new system greatly improves the speed of the multi-frequency coherence measurement and outperform the existing interferometer in terms of accuracy.
P Elleaume , C Fortgang , C Penel , . Measuring beam sizes and ultra-small electron emittances using an X-ray pinhole camera . Journal of Synchrotron Radiation , 1995 . 2 ( 5 ): 209 - 214 . DOI: 10.1107/S0909049595008685 http://doi.org/10.1107/S0909049595008685 .
Shiro Takano , Masaki Mitsuhiro , Ohkuma Haruo . X-ray imaging of a small electron beam in a low-emittance synchrotron light source . Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment , 2006 . 556 ( 1 ): 357 - 370 . DOI: 10.1016/j.nima.2005.08.108 http://doi.org/10.1016/j.nima.2005.08.108 .
K Iida . Measurement of an electron-beam size with a beam profile monitor using Fresnel zone plates . Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment , 2003 . 506 ( 1-2 ): 41 - 49 . DOI: 10.1016/S0168-9002(03)01392-5 http://doi.org/10.1016/S0168-9002(03)01392-5 .
H Sakai , M Fujisawa , K Iida , . Improvement of Fresnel zone plate beam-profile monitor and application to ultralow emittance beam profile measurements . Physical Review Special Topics-Accelerators and Beams , 2007 . 10 ( 4 ): 042801 DOI: 10.1103/PhysRevSTAB.10.042801 http://doi.org/10.1103/PhysRevSTAB.10.042801 .
Å Andersson , J Tagger . Beam profile measurements at MAX . Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment , 1995 . 364 ( 1 ): 4 - 12 . DOI: 10.1016/0168-9002(95)00221-9 http://doi.org/10.1016/0168-9002(95)00221-9 .
Å Andersson , M Böge , A Lüdeke , . Determination of a small vertical electron beam profile and emittance at the Swiss Light Source . Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment , 2008 . 591 ( 3 ): 437 - 446 . DOI: 10.1016/j.nima.2008.02.095 http://doi.org/10.1016/j.nima.2008.02.095 .
Hiramatsu S, Iwasaki H, Mitsuhashi T, et al. Measurement of small beam size by the use of SR interferometer[C]. Proceedings of Particle Accelerator Conference, 1999, 1: 492-494.
黄 国庆 , 陈 杰 , 陈 之初 , . 上海光源储存环X-ray针孔相机系统设计 . 核技术 , 2010 . 33 ( 11 ): 806 - 809 . http://mall.cnki.net/magazine/Article/XDWZ201003010.htm .
Guoqing HUANG , Jie CHEN , Zhichu CHEN , . X-ray pinhole camera system design for SSRF storage ring . Nuclear Techniques , 2010 . 33 ( 11 ): 806 - 809 . http://mall.cnki.net/magazine/Article/XDWZ201003010.htm .
黄 国庆 , 陈 杰 , 陈 之初 , . 上海光源X射线针孔相机控制系统设计 . 核技术 , 2011 . 34 ( 9 ): 641 - 645 . http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hjs201109001 .
Guoqing HUANG , Jie CHEN , Zhichu CHEN , . X-ray pinhole camera control system design for SSRF storage ring . Nuclear Techniques , 2011 . 34 ( 9 ): 641 - 645 . http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hjs201109001 .
陈 杰 , 叶 恺容 , 冷 用斌 . 上海光源同步辐射空间干涉仪研制 . 强激光与粒子束 , 2011 . 23 ( 1 ): 179 - 184 . http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=qjgylzs201101039 .
Jie CHEN , Kairong YE , Yongbin LENG . Development of Shanghai Synchrotron Radiation Facility synchrotron radiation interferometer . High Power Laser and Particle Beams , 2011 . 23 ( 1 ): 179 - 184 . http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=qjgylzs201101039 .
0
浏览量
25
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621