浏览全部资源
扫码关注微信
1.中国科学院等离子体物理研究所 合肥 230031
2.中国科学技术大学 合肥 230026
[ "徐宇, 女, 1992年出生, 2015年毕业于成都理工大学, 现为硕士研究生, 研究领域为核聚变辐射防护", "XU Yu, female, born in 1992, graduated from Chengdu University of Technology in 2015, master student, focusing on nuclear radiation protection of fusion reactor" ]
钟国强, E-mail:gqzhong@ipp.ac.cn ZHONG Guoqiang, E-mail: gqzhong@ipp.ac.cn
收稿日期:2017-10-02,
修回日期:2017-11-20,
纸质出版日期:2018-04-10
移动端阅览
徐宇, 徐国盛, 钟国强, 等. EAST实验场所与人员累积辐射剂量监测[J]. 核技术, 2018,41(4):040202
Yu XU, Guosheng XU, Guoqiang ZHONG, et al. Monitoring cumulative radiation dose of experimental sites and staff in EAST[J]. Nuclear techniques, 2018, 41(4): 040202
徐宇, 徐国盛, 钟国强, 等. EAST实验场所与人员累积辐射剂量监测[J]. 核技术, 2018,41(4):040202 DOI: 10.11889/j.0253-3219.2018.hjs.41.040202.
Yu XU, Guosheng XU, Guoqiang ZHONG, et al. Monitoring cumulative radiation dose of experimental sites and staff in EAST[J]. Nuclear techniques, 2018, 41(4): 040202 DOI: 10.11889/j.0253-3219.2018.hjs.41.040202.
实验型先进超导托卡马克(Experimental Advanced Superconducting Tokamak,EAST)运行时存在一定的电离辐射。依据电离辐射防护与辐射源安全标准和放射性工作人员职业健康管理办法,结合实验监测数据对EAST装置周边环境及工作人员的电离辐射影响状况进行了评估。采用光释光和固体核径迹法,对EAST装置大厅人员通道入口、屏蔽门内外、周边诊断室以及主控制室等场所的中子、γ辐射剂量进行累积监测。共布置了13个监测点,全年连续测量,以90 d为一周期进行剂量片更替与读数。统计分析了2010-2017年EAST装置上从事核辐射相关工作关键岗位人员的个人辐射剂量165人次,并利用Access软件建立了场所与人员的辐射剂量数据库。结果显示:扣除天然本底辐射后,装置大厅外的监测点以及职业人员年有效剂量均低于0.5mSv,满足电离辐射防护国家标准的要求。
Background
2
The reaction of D-D may generate radiation in the experiment of experimental advanced superconducting Tokamak (EAST)
and the total power can reach several tens of megawatts.
Purpose
2
This paper aims to assess the ionizing radiation effects of surrounding environment and staff.
Methods
2
Applying the optically stimulated luminescence and solid nuclear track
we did the cumulative monitoring of neutron and gamma radiation dose in experimental sites surrounding Tokamak device hall
i.e.
personnel entrance access
inside and outside of the screen door
peripheral diagnosis room and the main control room. Thirteen monitoring points were arranged for continuous measurement throughout years
taking a period of 90 d for dose tablets replacement and reading.
Results
2
From 2010 to 2017
there were 165 staffs on key positions in EAST
and a radiation dose database of the experimental sites and staff was established using the Access software. The effective dose of monitoring points outside the installation hall and the workers were less than 0.5 mSv after deducting natural background radiation.
Conclusion
2
This paper provides a preliminary reference for the management system and specification of radiation protection for Tokamak fusion devices.
李 凯 , 钟 国强 , 胡 立群 , . EAST托卡马克装置的核辐射监测系统 . 核技术 , 2015 . 38 ( 11 ): 110602 DOI: 10.11889/j.0253-3219.2015.hjs.38.110602 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.110602 http://www.j.sinap.ac.cn/hejishu/CN/abstract/abstract506.shtml .
Kai LI , Guoqiang ZHONG , Liqun HU , . Radiation monitoring system for EAST tokamak . Nuclear Techniques , 2015 . 38 ( 11 ): 110602 DOI: 10.11889/j.0253-3219.2015.hjs.38.110602 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.110602 http://www.j.sinap.ac.cn/hejishu/CN/abstract/abstract506.shtml .
柴 竹新 , 吴 宜灿 , 刘 伯学 . 核聚变装置EAST高可靠性辐射防护控制系统 . 核电子学与探测技术 , 2005 . 25 ( 1 ): 28 - 31 . http://www.irgrid.ac.cn/handle/1471x/200880?mode=full&submit_simple=Show+full+item+record .
Zhuxin CHAI , Yican WU , Boxue LIU . EAST high reliability radiation protection control system foe nuclear fusion device . Nuclear Electronics and Detection Technology , 2005 . 25 ( 1 ): 28 - 31 . http://www.irgrid.ac.cn/handle/1471x/200880?mode=full&submit_simple=Show+full+item+record .
P D Weng . The engineering design of the HT-7U tokamak . Fusion Engineering & Design , 2001 . 58 ( 11 ): 827 - 831 . http://www.sciencedirect.com/science/article/pii/S0920379601004793 .
Q Huang , Z Chai , Y Chen , . Design and analysis of the radiation shield and safety system for HT-7U Tokamak . Fusion Engineering & Design , 2003 . 69 ( 1 ): 749 - 756 . https://www.sciencedirect.com/science/article/pii/S0920379603001340 .
刘 建茹 , 耿 成 . 连云港市2005-2007年环境累积剂量监测与分析 . 科技风 , 2009 . 2 058 http://cqvip.com/qk/97196A/20091X/75747084504848574850485356.html .
Jianru LIU , Cheng GENG . Monitoring and analysis of environmental accumulative dose in Lianyungang from 2005 to 2007 . Technology Wind , 2009 . 2 058 http://cqvip.com/qk/97196A/20091X/75747084504848574850485356.html .
J P Li . Intelligent environmental neutron and gamma monitoring system . High Energy Physics & Unclear Physics , 1988 . 9 ( 2 ): 413 - 419 . http://en.cnki.com.cn/Article_en/CJFDTOTAL-KNWL198801002.htm .
J P Li , Y L Tang , B B Shao , . Intelligent environment neutron and gamma monitoring system . High Energy Physics and Unclear Physics , 1988 . 12 ( 1 ): 12 - 18 . http://cds.cern.ch/record/366315 .
Wan Y X, Weng P D, Li J G, et al . HT-7U superconducting Tokamak: physics design, engineering progress and schedule[R]. HT-7U Team, 2003.
黄 群英 . 核聚变实验装置HT-7U及大厅活化分析 . 核技术 , 2000 . 23 ( 8 ): 513 - 518 . http://kns.cnki.net/KCMS/detail/detail.aspx?filename=hjsu200008000&dbname=CJFD&dbcode=CJFQ .
Qunying HUANG . Activation analysis on HT-7U fusion experimental device . Nuclear Techniques , 2000 . 23 ( 8 ): 513 - 518 . http://kns.cnki.net/KCMS/detail/detail.aspx?filename=hjsu200008000&dbname=CJFD&dbcode=CJFQ .
0
浏览量
23
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621