浏览全部资源
扫码关注微信
环境保护部 核与辐射安全中心 北京 100082
[ "胡健, 男, 1988年出生, 2014年于哈尔滨工程大学获硕士学位, 现主要从事反应堆热工水力分析及试验研究工作", "HU Jian, male, born in 1988, graduated from Harbin Engineering University with a master's degree in 2014, focusing on thermal hydraulic analysis and experimental research of nuclear power" ]
温丽晶, E-mail:wenlj718@sina.com WEN Lijing, E-mail:wenlj718@sina.com
收稿日期:2017-09-08,
修回日期:2017-10-06,
纸质出版日期:2018-03-10
移动端阅览
胡健, 石兴伟, 雷蕾, 等. CERT试验台架传热特性比例分析失真评价[J]. 核技术, 2018,41(3):030602
Jian HU, Xingwei SHI, Lei LEI, et al. Assessment of heat transfer phenomenon scaling distortion in CERT[J]. Nuclear techniques, 2018, 41(3): 030602
胡健, 石兴伟, 雷蕾, 等. CERT试验台架传热特性比例分析失真评价[J]. 核技术, 2018,41(3):030602 DOI: 10.11889/j.0253-3219.2018.hjs.41.030602.
Jian HU, Xingwei SHI, Lei LEI, et al. Assessment of heat transfer phenomenon scaling distortion in CERT[J]. Nuclear techniques, 2018, 41(3): 030602 DOI: 10.11889/j.0253-3219.2018.hjs.41.030602.
非能动安全壳冷却系统(Passive containment cooling system,PCS)是大型先进压水堆核电厂专设安全系统之一,壳外冷却水膜在事故发生后对壳内的降温降压过程有着重要的作用。为了分析LOCA(Loss of Coolant Accident)事故工况下PCS整体响应过程的主要传热现象,验证PCS设计水膜覆盖率的安全裕度,本文利用安全壳专用分析程序分别对PCS原型系统和模拟试验台架(Containment safety vErification via integRal Test,CERT)进行建模,分析基准工况和恶劣工况下安全壳内的传热相关无量纲参数群(∏群)及其相似准则数(∏比)的变化,比较影响PCS降温降压能力的不同能量传递方式的重要程度,同时对其在试验台架上出现的失真度进行评价。结果表明,安全壳外冷却水膜建立后,壳内破口能量主要通过壳内壁面蒸汽冷凝和壳外壁面水膜蒸发载出,相应物理现象在台架模拟试验中应优先准确模拟;此阶段壳内热阱传热失真度较大,但由于其换热量很低可以忽略不计。通过传热特性失真评价认为,CERT试验台架可以有效模拟原型PCS在小水膜覆盖率时的传热现象。
Background
2
The cooling liquid film is very important during the depressurization and cooling down process of the passive containment cooling system (PCS) which is part of the passive reactor safety design.
Purpose
2
This study aims to analyze the main heat transfer phenomenon in PCS overall response process during loss of coolant accident (LOCA) accident and to verify the design liquid film coverage safety margin.
Methods
2
The calculating model of integral test facility and PCS prototype were established respectively using passive containment safety analysis code. Based on scaling analysis
the ∏ (similarity number) related to heat transfer in containment and the ∏ ratio between test facility and prototype were obtained in both base and severe accident condition. The importance degrees of different heat transfer modes affecting the containment cooled down were compared
and the heat transfer distortion was assessed.
Results
2
After the cooling liquid film was established
the break energy was mainly carried out by steam condensation inner shell and the liquid evaporation outer shell. The condensation and evaporation phenomenon was simulated accurately in the containment integral test.
Conclusion
2
Since the energy absorbed by heat sinks is tiny
its relatively large heat transfer distortion could be neglected. The assessment of heat transfer phenomenon scaling distortion show that the integral test facility could simulate heat transfer process of PCS prototype in low liquid film coverage condition effectively.
林 诚格 , 郁 祖盛 . 非能动安全先进核电厂AP1000 , : 北京 原子能出版社 , 2008 . 7 196 - 199 .
Chengge LIN , Zusheng YU . An advanced passive plant AP1000 , : Beijing Atomic Energy Press , 2008 . 7 196 - 199 .
Y M Kang , G C Park . An experimental study on evaporative heat transfer coefficient and applications for passive cooling of AP600 steel containment . Nuclear Engineering and Design , 2001 . 204 ( 3 ): 347 - 359 . https://www.sciencedirect.com/science/article/pii/S0029549300003654 .
韦 胜杰 , 殷 煜皓 , 胡 珀 , . 竖壁降液膜流动纵向及水平发展规律研究 . 原子能科学技术 , 2013 . 47 ( 2 ): 213 - 217 . DOI: 10.7538/yzk.2013.47.02.0213 http://doi.org/10.7538/yzk.2013.47.02.0213 .
Shengjie WEI , Yuhao YIN , Po HU , . Horizontal and longitudinal characteristics of water film falling on vertical plate . Atomic Energy Science and Technology , 2013 . 47 ( 2 ): 213 - 217 . DOI: 10.7538/yzk.2013.47.02.0213 http://doi.org/10.7538/yzk.2013.47.02.0213 .
Spencer D R, Brown W L, Woodcock J. Scaling for AP600 containment pressure during design basis accident[R]. WCAP-14845, Rev 3. USA: Westinghouse Electric Corporation, 1998.
Brown W L. Scaling of the AP600 containment large scale test facility[C]. 7th International Conference on Nuclear Engineering, Tokyo, Japan: Japan Society of Mechanical Engineers, 1999.
刘 卓 , 常 华健 . 台架缩比对冷凝液膜换热的失真评价 . 原子能科学技术 , 2014 . 48 ( 11 ): 1969 - 1975 . DOI: 10.7538/yzk.2014.48.11.1969 http://doi.org/10.7538/yzk.2014.48.11.1969 .
Zhuo LIU , Huajian CHANG . Assessment of scaling distortion in condensation film heat transfer . Atomic Energy Science and Technology , 2014 . 48 ( 11 ): 1969 - 1975 . DOI: 10.7538/yzk.2014.48.11.1969 http://doi.org/10.7538/yzk.2014.48.11.1969 .
孙 流莉 , 阳 祥 , 赵 瑞昌 , . 安全壳冷却试验蒸发特征数不确定度评定方法及其应用 . 动力工程学报 , 2015 . 35 ( 8 ): 687 - 692 . http://industry.wanfangdata.com.cn/dl/Export/Papers?ids=dlgc201508013&type=excel .
Liuli SUN , Xiang YANG , Ruichang ZHAO , . Uncertainty evaluation of evaporation dimensionless parameters obtained in performance test of a PCCS and the application . Journal of Chinese Society of Power Engineering , 2015 . 35 ( 8 ): 687 - 692 . http://industry.wanfangdata.com.cn/dl/Export/Papers?ids=dlgc201508013&type=excel .
叶 成 , 郑 明光 , 王 勇 , . AP1000非能动安全壳冷却水WGOTHIC分析 . 原子能科学技术 , 2013 . 47 ( 12 ): 2225 - 2230 . DOI: 10.7538/yzk.2013.47.12.2225 http://doi.org/10.7538/yzk.2013.47.12.2225 .
Cheng YE , Mingguang ZHENG , Yong WANG , . WGOTHIC analysis on AP1000 passive containment cooling water . Atomic Energy Science and Technology , 2013 . 47 ( 12 ): 2225 - 2230 . DOI: 10.7538/yzk.2013.47.12.2225 http://doi.org/10.7538/yzk.2013.47.12.2225 .
王 国栋 . 应用GOTHIC8.0程序分析AP1000核电厂PCS传热传质过程 . 原子能科学技术 , 2015 . 49 ( 1 ): 83 - 88 . DOI: 10.7538/yzk.2015.49.01.0083 http://doi.org/10.7538/yzk.2015.49.01.0083 .
Guodong WANG . Analysis of heat and mass transfer process for AP1000 NPP PCS using GOTHIC8.0 code . Atomic Energy Science and Technology , 2015 . 49 ( 1 ): 83 - 88 . DOI: 10.7538/yzk.2015.49.01.0083 http://doi.org/10.7538/yzk.2015.49.01.0083 .
石 兴伟 , 雷 蕾 , 兰 兵 , . PCS表面液膜覆盖率对安全壳完整性影响分析 . 核技术 , 2017 . 40 ( 1 ): 010602 DOI: 10.11889/j.0253-3219.2017.hjs.40.010602 http://doi.org/10.11889/j.0253-3219.2017.hjs.40.010602 http://www.j.sinap.ac.cn/hejishu/CN/abstract/abstract704.shtml .
Xingwei SHI , Lei LEI , Bing LAN , . The influence analysis of PCS surface liquid film coverage on the containment integrity . Nuclear Techniques , 2017 . 40 ( 1 ): 010602 DOI: 10.11889/j.0253-3219.2017.hjs.40.010602 http://doi.org/10.11889/j.0253-3219.2017.hjs.40.010602 http://www.j.sinap.ac.cn/hejishu/CN/abstract/abstract704.shtml .
N Zuber , G E Wilson , M Ishii , . An integrated structure and scaling methodology for severe accident technical issue resolution:development of methodology . Nuclear Engineering and Design , 1998 . 186 1 - 21 . DOI: 10.1016/S0029-5493(98)00215-5 http://doi.org/10.1016/S0029-5493(98)00215-5 .
0
浏览量
20
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621