浏览全部资源
扫码关注微信
1.中国科学院上海应用物理研究所 张江园区 上海 201204
2.中国科学院大学 北京 100049
[ "王健, 男, 1989年出生, 2011年毕业于华中科技大学, 现为博士研究生, 研究领域为加速器技术与低温工程", "WANG Jian, male, born in 1989, graduated from Huazhong University of Science and Technology in 2011, doctoral student, focusing on accelerator technology and cryog" ]
收稿日期:2017-03-13,
修回日期:2017-03-31,
纸质出版日期:2017-08-10
移动端阅览
王健, 刘以勇, 王淑华, 等. 钕铁硼低温永磁波荡器静态热负载研究[J]. 核技术, 2017,40(8):080104
Jian WANG, Yiyong LIU, Shuhua WANG, et al. Study on static heat loads of the NdFeB-based CPMU[J]. Nuclear techniques, 2017, 40(8): 080104
王健, 刘以勇, 王淑华, 等. 钕铁硼低温永磁波荡器静态热负载研究[J]. 核技术, 2017,40(8):080104 DOI: 10.11889/j.0253-3219.2017.hjs.40.080104.
Jian WANG, Yiyong LIU, Shuhua WANG, et al. Study on static heat loads of the NdFeB-based CPMU[J]. Nuclear techniques, 2017, 40(8): 080104 DOI: 10.11889/j.0253-3219.2017.hjs.40.080104.
低温永磁波荡器(Cryogenic Permanent Magnet Undulator,CPMU)利用稀土永磁材料钕铁硼或镨铁硼在低温下的剩磁及内禀矫顽力大幅增大的特性,通过使磁体工作在50-150 K的低温环境,获得相比于常规真空内波荡器(In-vacuum Undulator,IVU)高30%-50%的磁场性能。在磁气隙一定的条件下,CPMU可以在较小的周期长度下获得较大的磁场强度,这对于提升同步辐射光的亮度具有重要意义。本文介绍了上海光源(Shanghai Synchrotron Radiation Facility,SSRF)钕铁硼CPMU磁体冷却技术的研究进展,对CPMU的静态热负载进行了详细的理论分析及实验研究。CPMU静态热负载的理论分析方法在CPMU样件低温冷却实验装置得到了验证,并在完整钕铁硼CPMU样机中得到了应用。
Background
2
The magnetic performance of the cryogenic permanent magnet undulator (CPMU)
whose magnets work at the temperature of 50-150 K
can be enhanced by 30%-50% compared with that of the conventional in-vacuum undulator (IVU). As the magnetic characteristics of both the remanence and the intrinsic coercivity of NdFeB and PrFeB increase substantially with the decreasing of working temperature
the CPMU can gain higher peak field within shorter magnetic period under a given magnetic gap
which is of great significance to improve the brightness of the synchrotron radiation light source.
Purpose
2
This study aims to investigate the sources of the static heat loads of the CPMU and develop methods of evaluating and testing the heat loads.
Methods
2
The thermal conduction and the thermal radiation of the CPMU were analyzed theoretically. Two methods of analyzing the practical static heat loads of the CPMU were proposed
compared and tested by using the CPMU test device without magnet arrays.
Results
2
The method of analyzing the test heat loads that utilizes the measured temperatures of the girders and liquid nitrogen (LN
2
) tubes is better than the one that calculates the heat loads with the LN
2
flow rate and temperature rise in the tube.
Conclusion
2
The results were applied to the development of a full scale NdFeB based CPMU prototype.
T Hara , T Tanaka , H Kitamura , . Cryogenic permanent magnet undulators . Physical Review Special Topics-Accelerators and Beams , 2004 . 7 ( 5 ): 050702 DOI: 10.1103/PhysRevSTAB.7.050702 http://doi.org/10.1103/PhysRevSTAB.7.050702 .
Hara T, Tanaka T, Kitamura H. Insertion devices of next generation[C]. Proceedings of the 3rd Asia Particle Accelerator Conference, APAC2004, Gyeongju, Korea, 2004:216-220. http://www.mendeley.com/research/insertion-devices-next-generation-magnets-cryogenic/
Bizen T, Maréchal X, Seike T. Radiation damage in magnets for undulators at low temperature[C]. Proceedings of the 9th European Particle Accelerator Conference, EPAC'04, Lucerne Congress Centre, Switzerland, 2004:2092-2094. http://cds.cern.ch/record/823113
Kitegi C. Development of a cryogenic permanent magnet undulator at the ESRF[D]. Grenoble, France:Universite Joseph Fourier, 2008. http://hal.archives-ouvertes.fr/tel-00413012
Mcintosh G E. Design of subcooled pressurized cryogenic systems[C]. Transactions of the Cryogenic Engineering Conference-CEC, Chattanooga, Tennessee, US, 2007:865-871. http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.2908682