浏览全部资源
扫码关注微信
1.中国科学院高能物理研究所 粒子天体物理重点实验室 北京 100049
2.中国科学院高能物理研究所 核探测与核电子学国家重点实验室 北京 100049
3.中国科学院大学 北京 100049
4.中国科学院西安光学精密机械研究所 西安 710119
[ "权征, 男, 1985年出生, 2012年毕业于中国科技大学, 现为博士研究生, 研究领域为粒子天体物理与高能物理实验", "QUAN Zheng, male, born in 1985, graduated from University of Science and Technology of China in 2012, doctoral student, focusing on particle astrophysics and high energy experiments" ]
王志刚, E-mail:wangzhg@ihep.ac.cn WANG Zhigang, E-mail: wangzhg@ihep.ac.cn
收稿日期:2017-01-20,
修回日期:2017-03-08,
纸质出版日期:2017-05-10
移动端阅览
权征, 王志刚, 王俊静, 等. ICCD在三维成像量能器读出系统中的应用[J]. 核技术, 2017,40(5):050401
Zheng QUAN, Zhigang WANG, Junjing WANG, et al. Application of ICCD to the readout system for 3D imaging calorimeter[J]. Nuclear techniques, 2017, 40(5): 050401
权征, 王志刚, 王俊静, 等. ICCD在三维成像量能器读出系统中的应用[J]. 核技术, 2017,40(5):050401 DOI: 10.11889/j.0253-3219.2017.hjs.40.050401.
Zheng QUAN, Zhigang WANG, Junjing WANG, et al. Application of ICCD to the readout system for 3D imaging calorimeter[J]. Nuclear techniques, 2017, 40(5): 050401 DOI: 10.11889/j.0253-3219.2017.hjs.40.050401.
在宇宙线空间探测领域,三维成像量能器具有大几何因子和较强的粒子鉴别能力,因而具有广泛的应用前景。但是与二维量能器相比,其读出路数更多,电子学更复杂。增强电荷耦合器件(Intensifiedcharge-coupled device,ICCD)比传统的光电器件集成度高、体积小、功耗低、发热量低,正适合用于三维成像量能器的大规模读出,改善资源利用率。本工作主要讨论了ICCD在三维成像量能器方案中的应用,介绍了ICCD线性、光强分辨率测试结果以及对串扰进行修正的方法,最后给出使用欧洲核子中心(European Organization for Nuclear Research,CERN)提供的10 GeV电子束进行束流照射实验得到的能量重建结果,初步验证了ICCD用于三维成像量能器读出系统的可行性。
Background
2
Compared with common 2D calorimeters
3D imaging calorimeters have higher geometric acceptance and better background rejection performance for space particle physics experiments but they also have a large number of readout channels with more complicated electronics. The advantages of small size
low power consumption
low heat and high integration makes the image intensified charge-coupled device (ICCD) preferable to some traditional photoelectric devices like photomultiplier tube (PMT).
Purpose
2
This study aims to investigate the feasibility of ICCD readout for a 3D imaging calorimeter.
Methods
2
A 3D imaging calorimeter prototype with 250 channels and readout for an ICCD has been designed. Laser diodes were used as light sources to measure the linearity
light intensity resolution and crosstalk performance of the ICCD. The 10-GeV electron beam of the Super Proton Synchrotron at the European Organization for Nuclear Research (CERN-SPS) was employed to measure the response of the calorimeter and reconstruct the calorimetry.
Results
2
Experimental result of 10-GeV electron beam test shows the energy of incident particle can be reconstructed from ICCD image correctly.
Conclusion
2
The performance of ICCD with appropriate readout electronics can meet the requirements for a 3D imaging calorimeter.
C Adloff , L Basara , G Bigongiari , . The AMS-02 lead-scintillating fibres electromagnetic calorimeter . Nuclear Instruments and Methods in Physical Research Section A , 2013 . 714 147 - 154 . DOI: 10.1016/j.nima.2013.02.020 http://doi.org/10.1016/j.nima.2013.02.020 .
W B Atwood , A A Abdo , M Ackermann , . The large area telescope on the fermi gamma-ray space telescope mission . The Astrophysical Journal , 2009 . 697 ( 2 ): 1071 DOI: 10.1088/0004-637X/697/2/1071 http://doi.org/10.1088/0004-637X/697/2/1071 .
Zhang S N, Adriani O, Albergo S, et al. The high energy cosmic-radiation detection (HERD) facility onboard China's Space Station[C]. Proceedings of SPIE 9144, Space Telescopes and Instrumentation 2014:Ultraviolet to Gamma Ray, Montréal, Quebec, Canada, 2014.
K Yoshida , S Torii , T Yamagami , . Cosmic-ray electron spectrum above 100 GeV from PPB-BETS experiment in Antarctica . Nuclear Instruments and Methods in Physical Research Section A , 2008 . 42 ( 10 ): 1670 - 1675 . DOI: 10.1016/j.asr.2007.04.043 http://doi.org/10.1016/j.asr.2007.04.043 .
Hu B L, Gao X H, Wang L, et al. Research on ICCD for space observation of cosmic ray and dark matter[C]. Proceedings of SPIE 9144, Space Telescopes and Instrumentation 2014:Ultraviolet to Gamma Ray, Montréal, Quebec, Canada, 2014.
Photek Limited. Image intensifiers[EB/OL]. 2010. http://www.photek.com/pdf/datasheets/detectors/DS001_Image_Intensifiers.pdf http://www.photek.com/pdf/datasheets/detectors/DS001_Image_Intensifiers.pdf .
CETC44. High speed 300×400 CCD user guide[EB/OL]. http://www.coeri.com/UploadFiles/WEBEdit/20140519_5625.pdf http://www.coeri.com/UploadFiles/WEBEdit/20140519_5625.pdf .
F Yang , R H Mao , L Y Zhang , . Characterization of three LYSO crystal batches . Nuclear Instruments and Methods in Physical Research Section A , 2015 . 784 105 - 110 . DOI: 10.1016/j.nima.2014.11.103 http://doi.org/10.1016/j.nima.2014.11.103 .
R Y Zhu . Crystal calorimeters in the next decade . Physics Procedia , 2012 . 37 372 - 383 . DOI: 10.1016/j.phpro.2012.02.378 http://doi.org/10.1016/j.phpro.2012.02.378 .
C W Fabjan , F Gianotti . Calorimetry for particle physics . Review of Modern Physics , 2003 . 75 ( 4 ): 1243 - 1286 . DOI: 10.1103/RevModPhys.75.1243 http://doi.org/10.1103/RevModPhys.75.1243 .
K G Afanacieva , A M Artikovb , V Y Baranov , . Response of LYSO:Ce scintillation crystals to low energy gamma rays . Physics of Particles and Nuclei Letters , 2015 . 12 ( 2 ): 319 - 324 . DOI: 10.1134/S1547477115020028 http://doi.org/10.1134/S1547477115020028 .
Hamamatsu photonics k. k. Photomultiplier tubes:basics and applications[EB/OL]. 2007. http://www.hamamatsu.com/resources/pdf/etd/PMT_handbook_v3aE.pdf http://www.hamamatsu.com/resources/pdf/etd/PMT_handbook_v3aE.pdf .
S Agostinelli , J Allison , K Amako , . GEANT4-a simulation toolkit . Nuclear Instruments and Methods in Physical Research Section A , 2003 . 506 ( 3 ): 250 - 303 . DOI: 10.1016/S0168-9002(03)01368-8 http://doi.org/10.1016/S0168-9002(03)01368-8 .
0
浏览量
31
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621