浏览全部资源
扫码关注微信
同济大学 电气工程系 上海 201804
[ "项安, 男, 1965年出生, 2001年于南昌大学获博士学位, 研究领域为X射线安检相关技术", "XIANG An, male, born in 1965, graduated from Nanchang University with a doctor’s degree in 2001, focusing on X-ray security inspection technology" ]
梁鲁, E-mail: my1433145@163.com LIANG Lu, E-mail: my1433145@163.com
收稿日期:2016-02-25,
修回日期:2016-03-29,
纸质出版日期:2016-06
移动端阅览
项安, 梁鲁, 陈瑞焘. X射线管足跟效应的蒙特卡罗模拟与分析[J]. 核技术, 2016,39(6):060202
An XIANG, Lu LIANG, Ruitao CHEN. Monte Carlo simulation and analysis of X-ray tube's heel effect[J]. Nuclear techniques, 2016, 39(6): 060202
项安, 梁鲁, 陈瑞焘. X射线管足跟效应的蒙特卡罗模拟与分析[J]. 核技术, 2016,39(6):060202 DOI: 10.11889/j.0253-3219.2016.hjs.39.060202.
An XIANG, Lu LIANG, Ruitao CHEN. Monte Carlo simulation and analysis of X-ray tube's heel effect[J]. Nuclear techniques, 2016, 39(6): 060202 DOI: 10.11889/j.0253-3219.2016.hjs.39.060202.
X射线管的足跟效应是影响其性能的重要因素。为研究足跟效应对X射线能谱分布的影响
利用MCNP5软件构建了X射线管仿真模型
并设置了不同空间位置分布的探测器组
通过改变靶角、管电压和靶材料等参数研究X射线管的性能。仿真得到了靶角对X射线能谱的影响
以及在不同空间方位上X射线强度的分布
最后综合仿真结果得到了靶角、管电压以及靶材料对足跟效应的影响规律。仿真的方法和结果对X射线管的设计和使用提供了一定的理论指导。
Background
2
Heel effect of X-ray tube is an important factor which would affect its performance
especially for reflective X-ray tube.
Purpose
2
The study aims to research the impact of heel effect on X-ray spectral.
Methods
2
MCNP5 is adopted to create simulation model of X-ray tube and set up detector groups following different spatial position distribution. Then the performance of X-ray tube is analyzed by changing the parameters including target angle
tube voltage and target material.
Results
2
Simulation results show the impact of target angle upon X-ray spectral and X-ray intensity distribution in different spatial positions. In the final stage the impacts of target angle
tube voltage and target material on heel effect are shown.
Conclusion
2
Methods and results of this simulation provide certain theoretical guidance for the design and use of X-ray tube.
高 峰 , 李 志 . X射线管辐射剂量分布的理论分析与实验测量 . 物理实验 , 2007 . 27 ( 8 ): 25 - 27 . DOI: 10.3969/j.issn.1005-4642.2007.08.009 http://doi.org/10.3969/j.issn.1005-4642.2007.08.009 .
Feng GAO , Zhi LI . Theoretical analysis and experimental measurement of the radiation dose distribution of X-ray tube . Physics Experimentation , 2007 . 27 ( 8 ): 25 - 27 . DOI: 10.3969/j.issn.1005-4642.2007.08.009 http://doi.org/10.3969/j.issn.1005-4642.2007.08.009 .
M Bhat , J Pattison , G Bibbo , . Off-axis X-ray spectra:a comparison of Monte Carlo simulated and computed X-ray spectra with measured spectra . Medical Physics , 1999 . 26 303 - 309 . DOI: 10.1118/1.598517 http://doi.org/10.1118/1.598517 .
曹 琴琴 , 王 奇志 . 定向辐射X射线管的蒙特卡罗模拟分析 . 中国辐射卫生 , 2013 . 22 ( 6 ): 644 - 647 .
Qinqin CAO , Qizhi WANG . Monte Carlo simulation analysis of directional radiation X-ray tube . Chinese Journal of Radiological Health , 2013 . 22 ( 6 ): 644 - 647 .
X-5 Monte Carlo Team. MCNP-a general Monte Carlo N-particle transport code[R]. Version 5, Los Alamos National Laboratory, 2003
K P Ng , C S Kwok , F H Tang . Monte Carlo simulation of X-ray spectra in mammography . Physics in Medicine and Biology , 2000 . 45 ( 5 ): 1309 - 1318 .