
浏览全部资源
扫码关注微信
1. 西北核技术研究所,西安,710024
2. 西安交通大学 核科学与技术学院,西安,710049
纸质出版日期:2015-06-05
移动端阅览
田 耕, 欧阳晓平, 渠红光, 等. 低强度脉冲中子束的数字式n/γ分辨测量[J]. 核技术, 2015,38(6):060204
TIAN Geng, OUYANG Xiaoping, QU Hongguang, et al. Digital n/γ discrimination measurement of low intensity pulsed neutron[J]. Nuclear techniques, 2015, 38(6): 060204
田 耕, 欧阳晓平, 渠红光, 等. 低强度脉冲中子束的数字式n/γ分辨测量[J]. 核技术, 2015,38(6):060204 DOI: 10.11889/j.0253-3219.2015.hjs.38.060204.
TIAN Geng, OUYANG Xiaoping, QU Hongguang, et al. Digital n/γ discrimination measurement of low intensity pulsed neutron[J]. Nuclear techniques, 2015, 38(6): 060204 DOI: 10.11889/j.0253-3219.2015.hjs.38.060204.
针对低强度脉冲中子束测量,使用高速数字示波器作为数据采集设备,配合BC501A液体闪烁体探测器组建了数字式脉冲形状甄别(Digital Pulse Shape Discrimination
DPSD)测量系统,实现了中子的n/γ分辨测量。系统工作时采集并存储探测器输出的中子与γ射线的脉冲波形及其记录时刻,利用DPSD方法甄别中子实现了中子脉冲高度谱统计;系统具有连续记录和具备时间戳的采集窗记录两种工作方式以适应不同的脉冲中子束强度,并通过分析数据记录中脉冲波形的位置或时间戳,实现了中子事件的时间信息统计。使用该系统在Am-Be中子源上使用采集窗工作模式开展了实验,成功获得中子脉冲幅度谱、中子时间谱以及n/γ甄别谱。
Background: The traditional measurement methods in which the detectors are working in counting mode or current mode all have limitations in the measurement of low intensity pulsed neutron. Purpose: We aim to establish a method for low intensity pulsed neutron measurement to acquire the spectra of energy and time by digitalizing and analyzing the fast current pulse generated by detector as each single neutron induced. Methods: A digital pulse shape discrimination (DPSD) system for low intensity pulsed neutron measurement has been developed
which employs wideband digital oscilloscope as data acquisition device. With BC501A liquid scintillator detector
the system can acquire and store the waveforms of neutrons and γ-rays
and discriminate neutrons from all waveforms by DPSD algorithms. The system has two operation modes as “continuous acquisition” and “acquisition window with time stamp” for different event rates according to the intensity of pulsed neutron. Results: The function of pulse height analysis of neutrons is achieved
and time information of neutron’s arriving can be acquired by the analysis of the position of the waveform in the record or the time stamps. Experiment has been carried out with Am-Be neutron source with the operation mode of acquisition window
and the neutron pulse height spectrum
time spectrum and n/γ discrimination spectrum have been acquired. Conclusion: The spectra of energy and time of low intensity pulsed neutron can be measured by the digital method which employees wideband digital oscilloscope and digital signal processing algorithms
and has the advantage that all original waveforms of neutrons and γ-rays can be stored for further analysis. Abstract
0
浏览量
21
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621