浏览全部资源
扫码关注微信
1. 中国科学技术大学,合肥,230027
2. 中国科学院核能安全技术研究所 中国科学院中子输运理论与辐射安全重点实验室,合肥,230031
[ "通讯作者: 朱志强,E-mail: zhiqiang.zhu@fds.org.cn E-mail:zhiqiang.zhu@fds.org.cn" ]
纸质出版日期:2015-04-09
移动端阅览
贺 建, 朱志强, 黄群英, 等. Y型截止阀在液态铅铋中流阻测量与分析[J]. 核技术, 2015,38(4):040604
HE Jian, ZHU Zhiqiang, HUANG Qunying, et al. Test and analysis on the flow resistance of Y-type globe valve in the liquid lead-bismuth alloy[J]. Nuclear techniques, 2015, 38(4): 040604
贺 建, 朱志强, 黄群英, 等. Y型截止阀在液态铅铋中流阻测量与分析[J]. 核技术, 2015,38(4):040604 DOI: 10.11889/j.0253-3219.2015.hjs.38.040604.
HE Jian, ZHU Zhiqiang, HUANG Qunying, et al. Test and analysis on the flow resistance of Y-type globe valve in the liquid lead-bismuth alloy[J]. Nuclear techniques, 2015, 38(4): 040604 DOI: 10.11889/j.0253-3219.2015.hjs.38.040604.
液态铅铋合金是加速器驱动次临界系统(Accelerator Driven Sub-critical System
ADS)反应堆主选冷却剂材料之一,阀门是高温液态铅铋实验回路的重要组成部件之一,它的流动阻力大小直接影响整个回路装置的结构设计与安全运行。基于液态铅铋流体测量技术实验回路PREKY,开展了Y型截止阀在液态铅铋堆典型工况下的阻力特性测量实验研究,利用压差变送器获得压差实验数据,并与理论计算结果进行对比分析,验证了实验测量方法的可行性和测量结果的合理性。另外,获得了流速1.2–2.0m?s?1内液态铅铋介质中Y型截止阀流阻理论计算指数x值为2.4,此值可直接应用于未来液态铅铋实验回路流阻计算与分析工作。
Background: Liquid lead-bismuth eutectic (PbBi) has been proposed as one of mainly coolant materials for Accelerator Driven Sub-critical Systems (ADS) reactors
and the valve is a key component for flow regulation in high temperature liquid PbBi experimental loop. The flow resistance has a direct impact on the structural design and safe operation of the loop. Purpose: This study aims to reduce the resistance loss of the valve in high temperature liquid PbBi experimental loop of the drive system
ensuring the safe and stable operation of the loop. Methods: Based on liquid PbBi fluid measurement experimental loop PREKY
the resistance characteristics experiment of Y-type globe valve in the typical conditions of liquid PbBi reactor was performed
and the pressure datum were achieved by using differential pressure transmitter and compared with the theoretical calculation results. Results: The results verified the rationality of experimental results and reasonability of measurement method. In addition
the flow resistance theoretical calculated index on Y-type globe valve was proved to be 2.4 in the flow rate range of 1.2–2.0 m?s?1 for the liquid PbBi loop. Conclusion: The experimental results could be directly applied to calculation and analysis of flow resistance in liquid PbBi experimental loop in future. Abstract
0