[1]张钦华,唐忠锋,傅远,谢雷东,黎忠.双重密封法兰研制及其密封性能[J].核技术,2013,36(10):73-77.
ZHANG Qinhua, TANG Zhongfeng, FU Yuan, et al. Development and high temperature sealing performance study of double sealing flange[J]. Nuclear techniques, 2013, 36(10): 100602
[1]张钦华,唐忠锋,傅远,谢雷东,黎忠.双重密封法兰研制及其密封性能[J].核技术,2013,36(10):73-77. DOI: 10.11889/j.0253-3219.2013.hjs.36.100602.
ZHANG Qinhua, TANG Zhongfeng, FU Yuan, et al. Development and high temperature sealing performance study of double sealing flange[J]. Nuclear techniques, 2013, 36(10): 100602 DOI: 10.11889/j.0253-3219.2013.hjs.36.100602.
为解决普通法兰不能在高温腐蚀环境中长期使用的问题
设计加工了一种新型双重密封管道连接法兰。该法兰采用柔性石墨缠绕垫片和金属C形密封圈双重密封结构
特有的保护气设计使石墨缠绕垫片能在高温下不被氧化而长期稳定使用;同时建立一套试验台架对双重密封法兰高温密封性能进行测试。结果表明:该双重密封法兰在750 oC、0.7 MPa保温43 h条件下
其法兰整体泄漏率几乎为零
达到并满足使用要求。该技术解决了传统法兰采用石墨垫片易被氧化和采用金属垫片易被腐蚀而失效的缺点
在众多领域具有广泛应用。
Background: Flange is an important component used in the connection between pipes or between pipe and equipment. It is widely used in mechanical industry
petrochemical industry and nuclear industry. Ordinary flange could be oxidized or corroded under high temperature and strong corrosion condition
which leads to flange’s failure.Purpose: The aim is to design and validate the double sealing flange which could be used in high temperature and strong corrosion condition stably and supplied as a reliable detachable connection for petrochemical industry and nuclear industry under high temperature and strong corrosion environment. Methods: New flange is designed using flexible graphite spiral wound gaskets and C style metal ring double sealing structure. The unique protection gas design ensures the graphite spiral wound gasket used in high temperature reliably. Test bed is built to verify the stability of the flange. Results: Pressure reducing of graphite spiral wound gasket is only 0.01 MPa at 750 oC
0.7 MPa for 43 h
there is not obvious oxidation phenomenon at the same time. The leakage rate of metal C sealing ring is 1.51×10–4atm cc/s
and the metal C ring sealing’s performance meets the engineering requirements.Conclusion: The leakage rate of double sealing flange is almost zero under 0.7 MPa at 750 oC
which meets the engineering requirements. It avoids oxidizing at high temperature and corroding under strong corrosion condition.