
浏览全部资源
扫码关注微信
1. 复旦大学附属肿瘤医院核医学科PET中心
2. 复旦大学上海医学院肿瘤学系
3. 复旦大学附属肿瘤医院核医学科PET中心复旦大学上海医学院肿瘤学系
纸质出版日期:2013-10-01
移动端阅览
[1]王明伟,张勇平,郑宇佳,鲍晓,章英剑.~(18)F-FMISO的自动化合成改进及其肿瘤乏氧Micro-PET/CT显像[J].核技术,2013,36(10):40-45.
WANG Mingwei, ZHANG Yongping, ZHENG Yujia, et al. Improved automated production of 18F-FMISO and its tumor hypoxia imaging by Micro-PET/CT[J]. Nuclear techniques, 2013, 36(10): 100301
[1]王明伟,张勇平,郑宇佳,鲍晓,章英剑.~(18)F-FMISO的自动化合成改进及其肿瘤乏氧Micro-PET/CT显像[J].核技术,2013,36(10):40-45. DOI: 10.11889/j.0253-3219.2013.hjs.36.100301.
WANG Mingwei, ZHANG Yongping, ZHENG Yujia, et al. Improved automated production of 18F-FMISO and its tumor hypoxia imaging by Micro-PET/CT[J]. Nuclear techniques, 2013, 36(10): 100301 DOI: 10.11889/j.0253-3219.2013.hjs.36.100301.
1-H-1-(3-[18F]氟-2-羟基丙基)-2-硝基咪唑(18F-FMISO)是特异性肿瘤乏氧分子影像探针
其PET/CT显像指导肿瘤放疗靶区的勾画具有重要的临床应用价值。本文旨在建立18F-FMISO的改进的自动化合成方法
开展其肿瘤乏氧Micro-PET/CT显像研究。基于标记前体NITTP和简便的"一锅法"
利用升级、改进的Explora GN模块
依次完成放射氟化反应(NITTP(10 mg)
MeCN(1.0 mL)
120 oC
5.0 min)、水解反应(HCl(1.0 mol/L
1.0 mL)
130 oC
8.0 min)和HPLC分离纯化
自动化合成18F-FMISO。同时
采取分析型Radio-HPLC和Radio-TLC等方法检测各项质量控制指标
利用Micro-PET/CT进行荷SW1990胰腺肿瘤乏氧显像实验。结果表明
18F-FMISO的自动化生产时间约为65 min
放射化学产率为(30 5.0)%(未衰变校正
n=20)
放射化学纯度大于99%
比活度为(2.04 0.17)×1011Bq·mol–1
化学纯度得到改善。Micro-PET/CT显像表明
18F-FMISO在荷SW1990瘤鼠体内均呈全身分布
最佳的肿瘤乏氧显像时间为注射后3.0 h
肿瘤/肌肉吸收比为3.00 0.08。本研究建立了基于HPLC分离纯化而改进的18F-FMISO的自动化合成方法
而且其Micro-PET/CT肿瘤乏氧显像对比度高
为乏氧显像研究提供了可靠的制备方法和基本的实验参考依据。
Background: 1-H-1-(3-[18F]fluoro-2-hydroxypropyl)-2-nitroimidazole(18F-FMISO) is a specific molecular imaging probe for tumor hypoxia imaging
and its PET/CT imaging has an important clinical value for planning cancer radiotherapy target volume. Purpose: This study aimed to develop an improved
automated production of18F-FMISO and to perform Micro-PET/CT imaging of tumor hypoxia. Methods: Based on the labeling precursor NITTP and a simple "one-pot" method
an upgraded Explora GN module together with Explora LC was adopted to run radiofluorination(NITTP(10 mg)
MeCN(1.0 mL)
120oC
5.0 min)
hydrolysis(HCl(1.0 mol/L
1.0 mL)
130oC
8.0 min) and high performance liquid chromatography(HPLC) purification to produce18F-FMISO automatically. Moreover
Radio-HPLC and Radio-TLC were applied for the quality control
and Micro-PET/CT scanner for hypoxia imaging of SW1990 pancreatic tumor-bearing mice. Results: As results
18F-FMISO was obtained with the synthesis time for about 65 min
the radiochemical yield of(30 5.0)%(no decay corrected
n=20)
the radiochemical purity of above 99%
the specific activity of(2.04 0.17)×1011Bq· mol–1
plus with the enhanced chemical purity. Moreover
MicroPET/CT imaging showed that18F-FMISO presented whole-body distribution in SW1990 tumor-bearing mice
and the optimized time point for tumor hypoxia imaging was 3 h post injection with the uptake ratios of tumor-to-muscle of 3.00 0.08. Conclusion: In sum
we developed an improved
automated production of18F-FMISO with high performance liquid chromatography purification
high radiochemical yield
high specific activity and high reliability
and also verified its MicroPET/CT imaging of tumor hypoxia for providing experimental reference data.
0
浏览量
24
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621