Flash ROM芯片的存储阵列和外围电路均具有较高的辐射易损性
辐射损伤模式多样。为对其辐射敏感电路进行定位和分析
本文采用X射线微束开展局部辐照试验研究。分别研究了存储阵列
译码电路以及电荷泵等不同电路模块所引起的失效表征
利用错误位的逻辑地址映射图
总结错误分布规律
结合相应电路结构对其失效机理进行分析。辐照存储阵列会导致规则分布的0→1翻转错误
而译码电路出错会导致1→0的错误
电荷泵电路退化则会导致器件擦除和写入功能的失效。微束辐照结果可以有效补充全芯片总剂量效应考核的不足
为器件的抗辐射加固提供有益的参考。
Background: The failure phenomenon is difficult to analyze for the flash memories when the whole chip is exposed to irradiation since both the memory array and the peripheral circuits might be degraded.Purpose: In order to detect the radiation susceptibility and corresponding phenomenon of the related circuits that included in the flash memories
the X-ray microbeam is used as the radiation source instead of 60 Co.Methods: The failure phenomenon is studied respectively when the memory array
decoder circuits
the charge pump circuits as well as the I/O circuits are exposed to radiation.The errors are mapped according to the logical address and the failure mechanism is analyzed based on the circuits.Results: Irradiated on the memory array will lead to regularly distributed 0→1 bit flips
while only 1→0 are found when the row decoder is under exposure.Degradation of the charge pump circuits would lead to the erase/program functional failure.Conclusions: The results suggest that the X-ray microbeam radiation test is a good method for detecting the radiation susceptibility of the integrated circuits that contains lots of circuit modules.