The principle and dosimetric characteristic of a newly developed liquid core radioch romic OWG dosimeter (OWG-86) were described. The OWG-86 possesses higher OWG numerical aperture (leading to higher sensitivity and light-gathering power)
less V energy dependence and better environmental stability than FWT-70 dosimeter (USA).