The phenomena of nuclear fusion at room temperature have been studied using a gas discharge facility and about 104 neutrons per second have been detected.The neutron yield is controllable and reproduceable.The BF3 neutron detectors
the 6Li thermoluminescence films
the NE-213 organic liquid scintillation neutron spectrometer and the n-γ discrimination technique were used to diagnose the neutrons.It was confirmed that neutrons were emitted from the gas discharge facility.