[1]羊衍秋,杨通在,郝樊华,罗顺忠,何玉晖,姜涛,杨亮.SF_6示踪检测大型容器的动态泄漏[J].核技术,2010,33(04):312-315.
YANG Yanqiu YANG Tongzai HAO Fanhua LUO Shunzhong HE Yuhui JIANG Tao YANG Liang. Dynamic leakage test of a voluminous container using SF6 gaseous tracer[J]. Nuclear techniques, 2010, 33(4): 312-315.
SF6示踪技术是大型容器动态密封检测的有效方法。采用SF6示踪技术检测了一个9m3大型容器在内部炸药爆炸后各密封部位的气体泄漏率。介绍了泄漏检测实施技术
采用Kr为第二示踪剂
用以指示SF6示踪剂的爆后燃烧损失。结果表明
各检测部位的气体泄漏主要发生在爆后短时间内
泄漏率随时间的延长呈指数衰减
29h后基本平衡在10–12–10–13L/h的泄漏水平;炸药爆炸冲击波是气体泄漏的主要原因
爆后密封材料和机械密封结构基本未遭到破坏。
SF6 gaseous tracer is an effective technology for airtight test of voluminous containers. In this work
with SF6 gaseous tracer
the dynamic leakage of a voluminous inter-explosion container was tested. Kr was selected to indicate the loss of SF6 caused by the explosion-caused high temperature. The results showed that the gas leakage for various airtight points occurred a short time after explosion
and attenuated rapidly with time by exponential order to the stable leavl of 10–12–10–13 L/h in 29 hours after the explosion. As a result
the shock wave was considered as the chief matter responsible for gas leak. The material and mechanical structures for airtightness were not damaged.