LIU Tianwei 1 JIANG Fan 2 TANG Kai 2 WEI Qiang 2 1. Corrosion resistance of Ti films prepared on uranium by arc ion plating[J]. Nuclear techniques, 2009, 32(11): 823-827.
LIU Tianwei 1 JIANG Fan 2 TANG Kai 2 WEI Qiang 2 1. Corrosion resistance of Ti films prepared on uranium by arc ion plating[J]. Nuclear techniques, 2009, 32(11): 823-827.DOI:
single layer TiN films and gradient TiN films were deposited on uranium substrates by arc ion plating.The anodic polarization experiments in 50 μg/g Cl- solution indicate that E corr of the sample at a pulse bias of ?800 V increases to about 714 mV
with an I corr decrease of about two orders of magnitude.Studying on electrochemical corrosion mechanisms indicates that single layer films and gradient films become inactive by defect penetration through the substrate
hence decreased corrosion-resistance;while the inactivation of multi-layer films is due to layer malfunction
which makes it difficult for corrosive substances to reach the substrate.In this way the corrosion resistance is enhanced.