QIN Hongliang LI Ming SHI Hong. Improvement of the single bent crystal monochromator for 1W2A beam line at BSRF[J]. Nuclear techniques, 2009, 32(8): 568-571.
QIN Hongliang LI Ming SHI Hong. Improvement of the single bent crystal monochromator for 1W2A beam line at BSRF[J]. Nuclear techniques, 2009, 32(8): 568-571.DOI:
It was observed that the focused X-ray spots on the sample had an obvious shift and defocus as the beam currents decreased during the same run cycle at small angle X-ray scattering station
Beijing Synchrotron Radiation Facility (BSRF). A single bent crystal monochromator with a special geometry is proposed to solve those problems
and it meets the experimental requirements of small angle X-ray scattering station.