WANG Guicheng LENG Yongbin SUN Baogen TAO Xiaoping HE Xiaoye ZHAO Feng ZHOU Yaohua. Analysing the reason of break-down of film-mode resistor with PET carrier and it’s improvement program[J]. Nuclear techniques, 2002, (1): 41-45.
WANG Guicheng LENG Yongbin SUN Baogen TAO Xiaoping HE Xiaoye ZHAO Feng ZHOU Yaohua. Analysing the reason of break-down of film-mode resistor with PET carrier and it’s improvement program[J]. Nuclear techniques, 2002, (1): 41-45.DOI:
The film-mode resistor used for the wall-current monitor with the carrier of PET usually broke-down under the strong radiation in about a half year in the LINAC tunnel of NSRL. A survey of the reason was made and a new type film-mode resistor with ceramic carrier was developed. It’s lifetime can be expected to be a few years in the LINAC tunnel of NSRL.