LIU Shuhuan1, 2 JIANG Xinbiao1 ZHONG Yunhong1 ZHANG Wenshou1 LIU Nannan1 WANG Wushang1 ZHOU Hui1 SHAO Beibei2 1. Measurement the parameters of the irradiation field for the fast neutron device in reactor[J]. Nuclear techniques, 2006, (9): 660-664.
LIU Shuhuan1, 2 JIANG Xinbiao1 ZHONG Yunhong1 ZHANG Wenshou1 LIU Nannan1 WANG Wushang1 ZHOU Hui1 SHAO Beibei2 1. Measurement the parameters of the irradiation field for the fast neutron device in reactor[J]. Nuclear techniques, 2006, (9): 660-664.DOI:
The neutron spectra and flux of the fast neutron device in reactor are measured with multiple foil activa- tion method in the present paper
and the uncertainties of the measurement spectra is analyzed with Monte Carlo method. Thermoluminescent detector (TLD) is used to measure γ-ray dose rate of the device. The values of the ex- periment results prove that the indexes of the designed device are satisfied well.