Fluence rate distributions of neutrons emitted from intermediate energyreactions of 50MeV/u~12C-ion on thick Be
Cu and An targets have been measuredwith the threshold detectors. The neutron dose equivalent rate distributions in theheavy ion accelerator target area were obtained by using the conversion factors forneutron fluence rate to neutron dose equivalent rate.