SUN Lu SUN Licheng YAN Changqi. Thermal-hydraulic analysis of bayonet cooling thimble in fuel drain tank of ORNL 10MW MSRE[J]. Nuclear techniques, 2012, 35(10): 790-794.
SUN Lu SUN Licheng YAN Changqi. Thermal-hydraulic analysis of bayonet cooling thimble in fuel drain tank of ORNL 10MW MSRE[J]. Nuclear techniques, 2012, 35(10): 790-794.DOI:
The residual heat removal system of molten salt reactor designed by ORNL
using molten salt as fuel and draining the fuel into fuel drain tank after shutdown of the reactor
removes the decay heat by the circulation of water through the bayonet cooling thimbles in the fuel drain tank.According to structural features of the bayonet cooling thimbles in ORNL 10 MW molten salt reactor experiment(MSRE)
this paper presents the analytical results of the influence of the width of gas gap and the width of steam riser on the heat removal ability and the natural circulation of the cooling water
etc.The analysis results show that
when the width of gas gap range from 3.1 mm to 5.1 mm
the change of heat dissipation power and natural circulation flow rate are both less than 5%;when the width of steam riser changes from 3.6 mm to 5.1 mm
the flow mass of the natural circulation change from 1.9 kg/s to 4.79 kg/s
with a slightly effect on the heat transfer efficiency of the system.