目前,国际上应用最广的两种辐射变色染料是六羟乙基副品红氰化物(
hexahydroxyethyl pararosaniline cyanide
HPR-CN)及副品红氰化物(
pararosaniline cyanide
PR-CN)。本工作是以自行合成的HPR-CN和PR-CN为剂量计,与美国Far West Technology Inc.生产的HPR-CN进行了纯度、灵敏度及吸收谱等对比,验证了不同溶剂、不同隐色染料氰化物浓度的剂量测量体系对量程线性的影响。
The sensitivities and absorption spectra of two kinds of radiochromic dye cyanide —hexahydroxyethyl pararosaniline(HPR-CN)and pararosaniline cyanide(PR-CN)syn-thesised in our own laboratory are identified spectrophotometrically. The results show that the dosimetric characteristics of HPR-CN are nearly the same as of the product of Far West Technology Inc.
U.S.A.. The gamma ray responsibilities of these two radiochromic dye cyanide dosimeter solutions are evaluated.