浏览全部资源
扫码关注微信
中国科学院近代物理研究所
收稿日期:1986-11-14,
纸质出版日期:1988-02
移动端阅览
王素芳, 蔡薇, 郑纪文, 等. 用于短寿命核素测量的简单传送带装置[J]. 核技术, 1988,11(2):49-51,64.
Sufang Wang, Wei Cai, Jiwen Zheng, et al. A simple tape transport system to measure the nuclei with short lifetime[J]. Nuclear techniques, 1988, 11(2): 49-51,64.
本文介绍一个用于秒级半衰期核素测量的简单传送带装置。把反应产物收集到一条镀铝Mylar箔上,然后极快地传送到测量点进行测量。带子运行时,靶室真空从2.67mPa降至6.67mPa,带子停止后靶室真空立即恢复。文中还给出了测得的
12
C+
112
Sn反应产物的
γ
能谱。
In this paper a simple tape transport system to measure the nuclei with half-live T
1/2
≥1 s was described. The reaction products are collected on a Mylar foil
which was then transported immediately to the measurement spot. The vacuum in the reaction chamber was 2.67 mPa and while the tape was pulled the vacuum decreased to 6.67 mPa. The vacuum was recovered immediately to the original value when the tape's movement is stopped. a
γ
ray spectrum of products from reaction
12
C+
112
Sn was also given.
H. K. Carter and R. L. Mlekodaj , Nucl. Instr. Meth. , 128 ( 1975 ), 611 。
王素芳 等 , 12 C十 112 Sn短寿命蒸发余核的研究 , 高能物理与核物理 ( 待发表 )。