C年代测量法是同位素年代测量中精确性好的一种方法。目前
14
C实验室广泛采用液体法。但国内外商品液体闪烁计数器由于本底高而不能直接用于低水平测量。经采用加厚屏蔽,线路改进等措施后的FJ-353液体闪烁计数器的本底为6cpm,效率70%,优值820。为适应地学、考古、环保、海洋等学科中探测低水平
3
H、
14
C的需要,我们参考YSJ-76液闪
[1]
研制了YSJ-SH79低本底自动液体闪烁计数器。
A low background automatic scintillation counter YSJ-SH79 was developed. In this instrument we adopted the technology of optical crosstalk discrimination and the four layer shield combined by lead
silver
copper and perspex. The samples are fed from underneath and samples can be automaticlly measured in turn. The quality reached by the instrument for
14
C is as follows: the background is 2.222 cpm the detection efficiency is 78% and the figure of merit is 2738.