最新刊期

    卷 47 , 期 3 , 2024

      INVITED REVIEW

    • “在γ能谱分析领域,专家总结了级联符合相加效应校正技术的发展,提出了未来研究方向。”
      FAN Yuanqing,LI Qi,ZHANG Xinjun,ZHAO Yungang,JIA Huaimao,ZHANG Ruiqin,LI Ruiying,NIU Yazhou,WANG Shilian
      Vol. 47, Issue 3, Article number: 030001(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030001
      摘要:As a passive nondestructive nuclear technique, gamma ray spectrometry is used in many radioactivity laboratories. Gamma-ray spectrometry enables the identification of radionuclides in a sample from their emitted photon energy and calculation of their activities from the number of photons collected for each energy. However coincidence summing effects will influence the reliability of both radionuclide identification and calculation of activity. Coincidence summing effects appear when sources emitting coincident gamma rays are measured via gamma-ray spectrometry. Those effects that result in losses from the full energy peaks and enhancement of sum peaks influence the accuracy of the spectral analysis. To eliminate this influence, many correction methods have been established. Research on the coincidence summing effect (CSE) originated in the 1960s. Subsequently, many algorithm-based generation mechanisms of CSE have been built together with the development of corresponding correction software. Massive amounts of technological information on and achievements about coincidence summing correction have been reported by researchers from different countries, hence several intercomparisons of these methods, and self-consistency testing of cascaded additive effect correction algorithm were organized by the International Committee for Radionuclide Metrology (ICRM). Based on a detailed summary of the development history of correction methods, the CSE mechanisms, correction algorithms, correction software, and application of correction techniques were reviewed in this paper. Cobalt-60 was taken as an example to illustrate the influence of the summing-in and summing-out effects, with correction equations based on different measurement geometries and considering the impact of angular correlations. Meanwhile, the performance of different algorithms and software were compared and analyzed. Combined with the current research status, some suggestions are presented for future research for domestic researchers on the coincidence summing effect correction. First, the efficiency must be accurately established for the geometrical conditions of the measurement. Second, the number of cascades in the algorithm must be taken into account owing to its influence on the results. Third, correction software with a user-friendly interface and database of accurate decay schemes should be developed.  
      关键词:Coincidence summing effect;Gamma-ray spectrometry;Summing-out effect;Summing-in effect   
      284
      |
      130
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642141 false
      发布时间:2024-10-25

      SYNCHROTRON RADIATION TECHNOLOGY AND APPLICATIONS

    • “上海光源新增双插入件工程,解决了加速器安装调试难题,为其他光源建设提供参考。”
      JIAO Guangwei,TIAN Shunqiang,XIANG Shengwang,ZHU Ya,LIU Xinzhong,WU Shuai
      Vol. 47, Issue 3, Article number: 030101(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030101
      摘要:BackgroundThe Shanghai Synchrotron Radiation Facility (SSRF) is a user facility that requires continuous addition of new beamlines to meet the needs of an increasing number of users. Adding new insertion devices (IDs) to the synchrotron radiation light source is a complex and critical task.PurposeThis study aims to highlight the important considerations of dual IDs installation and commissioning when adding new beamlines to synchrotron light sources.MethodsThe newly added dual IDs 04IVU (undulator) and 04Wigger for new beamline added to SSRF were taken as an example, key tasks that need to be addressed in the accelerator aspect of engineering were presented in details. Firstly, the design parameters and magnetic measurement results of the IDs were introduced, and the SPECTRA program was employed to calculate the spectral brightness of dual IDs. Then, problems encountered during the installation process and their solutions were discussed, and an orbit feedforward compensation system equipped with corrector coils for mitigating orbit distortions caused by the IDs was implemented. Finally, the significance, methods, and results of vacuum cleaning work in the front-end area, together with a summary of the issues encountered during the trial operation and corresponding solutions were outlined.ResultsThe maximum spectral brightness of 04IVU and 04Wiggler are 5.86×1019 Photon·s-1·mm-2·mrad-2·(0.1% B.W.)-1 and 2.75×1015 Photon·s-1·(0.1% B.W.)-1 at photon energy of 3 keV, respectively. After compensation, the distortions of 04IVU and 04Wiggler are reduced to below 2 μm.ConclusionThe dual IDs have been successfully installed and commissioned. This study provides reference value for installation and commissioning of accelerators associated with the new beamline in other synchrotron radiation light sources.  
      关键词:Synchrotron radiation light source;Shanghai Synchrotron Radiation Facility (SSRF);Beamline project;Insertion devices (IDs)   
      154
      |
      48
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642484 false
      发布时间:2024-10-25
    • “在能源材料研究领域,科学家利用机器学习算法,通过两张谱学背景图像完成背景图像序列预测建模,显著提升全场纳米谱学成像实验效率。”
      XING Yanjun,GAO Ruoyang,ZHANG Ling,TAO Fen,LIU Yi,DENG Biao
      Vol. 47, Issue 3, Article number: 030102(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030102
      摘要:BackgroundFull-field transmission X-ray microscopy (TXM)–X-ray absorption near-edge structural (XANES) (TXM-XANES) is an imaging method that combines TXM and XANES. By measuring the TXM images of multiple energy points before and after the K-edge of the element of interest, the distribution of elemental chemical states in the sample can be determined. Conventional TXM-XANES data requires the acquisition of images and background images at each energy point, which results in a large data volume and extended acquisition time. At the nanoscale, the instability of the mechanical structure and the movement of the sample may impact the TXM-XANES data analysis.PurposeThis study aims to use machine learning methods to achieve background-image sequence prediction modeling using only two spectral background images to reduce the data volume and shorten the acquisition time.MethodsMachine learning, polynomial regression, and linear interpolation were used to generate background image sequences. A prediction model of the complex linear relationship between image grayscale values, pixel points, energy, and other related features based on the known data was established. Subsequently, the entire background image sequence could be predicted using only two spectral background images. Finally, 2D energy distribution maps obtained by conventional TXM-XANES method and this improved TXM-XANES method for standard powder samples and lithium battery cathode material sample were compared and analyzed in details.ResultsThe proposed method achieves complete background-image sequence prediction modeling using only two spectral background images. The comparison results show that the proposed method requires a lower data volume and shorter acquisition time than the conventional TXM-XANES methods, which can significantly improve the experimental efficiency of TXM-XANES.ConclusionsThis study addresses the issues of prolonged data gathering time and poor experimental efficiency in TXM-XANES by developing a machine learning model that builds complex linear relationships between pixel values and related features, such as location and color, using machine learning. Using the two TXM-XANES background images for full-sequence background prediction achieves rapid prediction of the entire background image sequence.  
      关键词:Full-field nanoscale imaging;Polynomial regression;Linear interpolation;Image sequence prediction   
      158
      |
      68
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642256 false
      发布时间:2024-10-25

      NUCLEAR CHEMISTRY, RADIOCHEMISTRY, RADIOPHARMACEUTICALS AND NUCLEAR MEDICINE

    • “最新研究揭示了钚在不同水体中的形态分布,发现水硬度尤其是钙离子浓度是影响钚形态的重要因素。”
      ZHENG Qi,WANG Fan,ZHANG Fan,LI Cong,CHEN Lifeng,WEI Yuezhou
      Vol. 47, Issue 3, Article number: 030301(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030301
      摘要:BackgroundPlutonium is an important element for nuclear energy production and radioactive waste disposal, and evaluating its species distribution in natural water systems is essential for investigating its migration behavior. Recently, with the advancements in related research, some new plutonium species have been discovered and confirmed, hence previous related research is now inadequate for accurately describing the species distribution of plutonium in solutions.PurposeThis study aims to understand the speciation distribution of plutonium in different water composition systems.MethodsThe geochemical calculation software PHEEQC was employed to systematically evaluate the effects of the pH value and coexisting ion concentration on the species distribution of plutonium. The plutonium species proportion in different natural water systems was estimated in according with the latest thermodynamic data embedded into PHEEQC software.ResultsThe results reveal that hexavalent plutonium in oxidized groundwater with low hardness mainly exists as PuO22+ or PuO2CO3 under acidic conditions, whereas PuO2(CO3)22- or PuO2(CO3)34- dominate under neutral or alkaline conditions. Although PuO22+ and PuO2CO3 are the main species of plutonium in acidic environments, CaPuO2(CO3)32- is the dominant species under neutral or basic conditions whereas the calcium concentration is high in the solution.ConclusionsTherefore, the hardness of water (particularly, the calcium concentration) can be concluded to be among the important factors affecting the species of plutonium and must be carefully considered in the geological disposal of plutonium.  
      关键词:Plutonium;Species;PHREEQC;Underground water composition   
      146
      |
      53
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642147 false
      发布时间:2024-10-25
    • “在快堆乏燃料干法后处理领域,专家利用冷指结晶装置,探索了LiCl熔盐中Sr、Ba分离规律,为纯化废盐、实现熔盐重复利用提供参考。”
      LIN Qin,WANG Yujiao,CHENG Ming,SUN Bo,FU Haiying,DOU Qiang,ZHOU Jinhao,ZHOU Zaichun,LIU Qiuhua
      Vol. 47, Issue 3, Article number: 030302(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030302
      摘要:BackgroundAn electrolyte waste salt containing LiCl and various products is generated during the pyroprocessing of spent nuclear fuel in metal fast reactors. Separating metal impurities from waste salt can purify molten salt, facilitate salt recycling, and reduce the amount of waste salt, achieving waste minimization.PurposeThis study aims to investigate the effects of key factors on the application of the cold finger crystallization method used for removal of Sr and Ba from molten LiCl salt.MethodsA homemade cold finger experimental apparatus was applied to the experimental removal of two alkaline earth metals, Sr and Ba, from molten LiCl salt, and Fluent software was employed to simulate the application of cold finger crystallization equipment during dry reprocessing. The effects of crystal growth time, initial crystallization temperature, and initial SrCl2/BaCl2 concentrations on the removal ratio of the crystalline salt during the process were analyzed.ResultsThe initial temperature of molten salt is a critical factor that influences cold finger separation efficiency. When the initial temperature reaches 660 ℃, the removal efficiency improves. Moreover, when the impurity contents of Sr and Ba in molten salt are lower than 0.55%(w/w), the removal efficiency of the cold finger crystallization method can exceed 80%. Further analysis shows that the removal effects of different parts of molten salt crystals differ. The solvent salt at the top of the molten salt crystal is better, and the removal ratio of the bottom and inner salts is lower. Therefore, the optimal conditions for removing Sr and Ba from LiCl crystalline salt require an initial temperatures of 660~670 ℃, an airflow intensity of 10 L·min-1, and a growth time of 20 min. Under these optimal conditions, the removal ratio can reach 90%.ConclusionsThe proposed approach is feasible for purifying solvent salts from electrolyte waste molten salt via cold finger crystallization. This study provides a reference for purifying waste salt and reusing molten salt.  
      关键词:Molten LiCl salt;Cold finger;Alkaline earth metal;Separation   
      76
      |
      52
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642380 false
      发布时间:2024-10-25
    • “在环境水中14C测量领域,研究人员采用湿法氧化体系和紫外氧化技术,成功提取水中碳,为提高测量精度提供新方法。”
      LI Lei,LIU Wei,MA Yuhua,LI Zhiqiang,DENG Ke,ZENG Linlin,XU Yong
      Vol. 47, Issue 3, Article number: 030303(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030303
      摘要:BackgroundExtraction of carbon from water is a crucial preprocessing step for measuring 14C in environmental waters using liquid scintillation spectrometry.PurposeThis study aims to explore the optimal technological conditions for extracting carbon from water using wet oxidation method.MethodsA wet oxidation system combining sodium persulfate and Fenton's reagent, along with phosphoric acid acidification and nitrogen bubbling, were employed for the wet oxidation carbon extraction experiments on two types of water samples with known (deionized water + sucrose) and unknown carbon components, each with a volume of 10 L. Simultaneously, carbon extraction experiments were conducted on the water samples having unknown carbon component, using a combination of wet oxidation and 185 nm ultraviolet (UV) oxidation so as to determine the optimal timing and sequence of reagent addition, as well as the optimized reagent dosage and ratio. Further experiments under optimized conditions were conducted to obtain more results for deep analysis.ResultsUnder the optimized conditions, after a 3-h reaction at 90 °C, the organic carbon extraction rate for the known carbon component (deionized water + sucrose) exceeds 96%. The total carbon extraction rate from the unknown carbon component water is (96.8±0.3)%, with an inorganic carbon extraction rate >98.5%, and an organic carbon extraction rate of (93.4±0.2)%, while the oxidation rate of tannic acid-type organic compounds is only (88±0.2)%. After the combination of wet oxidation and 185 nm UV oxidation, the total carbon extraction rate for the unknown carbon component increases to (98.3±0.5)%, with an inorganic carbon extraction rate ≥99% and an organic carbon extraction rate that can reach (95.6±1.4)%.ConclusionsResults of this study indicate that wet oxidation alone cannot represent the carbon recovery rate in actual water samples using typical organic compound carbon recovery rates. The combination of wet oxidation and 185 nm UV oxidation proves to be a more effective method for carbon extraction from water.  
      关键词:14C in water;Inorganic carbon;Organic carbon;Ultraviolet;Wet oxidation   
      79
      |
      48
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50615477 false
      发布时间:2024-10-25

      NUCLEAR ELECTRONICS AND INSTRUMENTATION

    • “东方超环装置上极紫外光谱诊断系统采用CCD探测器集光谱图像数据,针对硬X射线干扰,设计了基于FPGA的EUV光谱图像处理系统,有效去除噪声点,提升光谱数据可观测性。”
      SUN Bo,LIU Chong,ZHANG Hongming,LYU Bo,YIN Xianghui,LIN Zichao,SHEN Yongcai,JI Huajian,FU Jia,WANG Fudi,HU Kui,FAN Yu,MAO Liyu,ZENG Chao
      Vol. 47, Issue 3, Article number: 030401(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030401
      摘要:BackgroundDuring the data acquisition of an extreme ultraviolet (EUV) spectroscopic diagnostic system in experimental advanced superconducting Tokamak (EAST), significant amounts of one-pixel noises are consistently observed. This is attributed to the influence of hard X-ray on the charge coupling device (CCD) detector.PurposeThis study aims to detect and denoise spectral images in the EUV spectral image processing system based on the field programmable gate array (FPGA).MethodsFirst of all, based on limiting filtering algorithm, spectral image processing was optimized by replacing fixed limiting thresholds and sample deviations using parameters such as standard deviation and deviation from the mean, and Andor Solis software to was applied to converting the SIF format spectra to BMP format spectral images. Then, data discrimination method was combined with limiting filtering algorithm to process spectral image data in stages according to the setting working area of the algorithm. Finally, a simulation test module was designed to process the video data converted from EUV spectral images in AX7Z100 ZYNQ FPGA platform, simulating the actual acquisition process for functional testing of the system. To assess the system's capacity to protect effective spectral data, the image data was transferred to one-dimensional spectral data for comparative analysis.ResultsBased on the experimental results, the EUV spectral image processing system of this study can effectively eliminate noise data points in the spectral image while essentially maintaining the integrity of the spectral data.ConclusionsThis study enhances the processing of the spectral data and provides a new technological path for EUV spectral image processing.  
      关键词:Extreme ultraviolet;Image processing;Field programmable gate array;Image denoising   
      141
      |
      60
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642002 false
      发布时间:2024-10-25
    • “第三代SiC半导体探测器在反应堆堆芯剂量监测领域取得新进展,实现了中子转换层厚度优化,具有良好的线性响应和n/γ剂量响应范围,为核电现场监测提供解决方案。”
      SHI Haining,YING Hong,ZHANG Tao,TANG Tang,SONG Jinlin,GONG Pin,TANG Xiaobin
      Vol. 47, Issue 3, Article number: 030402(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030402
      摘要:BackgroundDetectors based on the third-generation semiconductor material silicon carbide (SiC) offer several important advantages, such as compactness, faster charge-collection times, and easier n/γ identification, and they are widely used in reactor core dose monitoring.PurposeIn this study, the n/γ signal amplitude, neutron fluence rate, and linear response calibration performances were tested systematically for a self-developed third-generation SiC semiconductor detector.MethodsFirstly, the neutron conversion layer material 6LiF (with a 95% abundance of 6Li) was sprayed onto a SiC substrate using electron beam evaporation vacuum coating technology to achieve the optimized thickness of 25 μm for the self-developed third-generation SiC semiconductor detector. Then, 241Am α radioactive source (activity 9.37×103 Bq) was used to observe α particle response signal amplitude, and γ response testing of radiation was conducted in the 137Cs γ source (activity 6.23×107 Bq) environment. In addition, the SiC detector's neutron flux response linearity, γ dose rate response linearity and calibration of neutron fluence rate response linearity were measured in the standard radiation field systems.ResultsThe measurement results show that the SiC semiconductor detector has a linear fit of R² = 0.996 9 in the neutron fluence rate range of 1×103~1×106 cm-2∙s-1, with a good linear response, and the response range of the neutron/gamma dose is 0.005~20 Gy∙h-1.ConclusionThe SiC detectors with such good n/γ performance can be used for real-time and accurate monitoring of neutron and gamma doses in nuclear power field reactors.  
      关键词:SiC detector;Neutron fluence rate;Gamma dose;Linear responses   
      144
      |
      72
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642003 false
      发布时间:2024-10-25
    • “在硅光电倍增器领域,研究者设计了一款信号放大电路,有效滤除环境噪声,具有快上升时间和低输入噪声,为探测器研究提供新方向。”
      TANG Chenyang,CHEN Xinnan,GAO Chunyu,LI Yupeng,WANG Xiao,TANG Xiuzhang
      Vol. 47, Issue 3, Article number: 030403(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030403
      摘要:BackgroundThe silicon photomultiplier (SiPM) is sensitive to environmental noise, its performance is greatly affected by ambient noise.PurposeThis study aims to design a negative-feedback selective amplifier circuit for SiPM coupled plastic scintillator detector to reduce the noise and improve the overall performance of SiPM.MethodsIt is compared with the traditional OPA657 transimpedance feedback amplifier circuit. The circuit consisted of an RC filter input and an integrated operational amplifier AD8014 with advantages of a high gain and low input noise. The CR high-pass filter circuit was used as the comparator signal input to further filter out signal noise and prevent signal reflection from interfering with the amplifier. The experimental circuit is simulated using Micro-cap12 to obtain the relevant circuit parameters. Finally, the dark noise level and signal consistency of a 137Cs source at room temperature was record, and performance of this amplifier circuit for SiPM coupled plastic scintillator detector was compared with that of the traditional OPA657 transimpedance feedback amplifier circuit. [Results and Conclusions] Comparison results show that the proposed circuit effectively filters out ambient noise and exhibits a fast rise time. The output pulse rise time is found to be less than 12 ns, and the dark noise level is observed to be less than 30 mV, which are better than those of the transimpedance amplifier circuit.  
      关键词:SiPM;Plastic scintillator;Circuit signal simulation;Dark noise and consistency measurements   
      169
      |
      77
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642145 false
      发布时间:2024-10-25
    • “在放射源定位领域,专家利用中子探测器和蒙特卡罗方法,成功实现了对密封容器内放射源的精确定位,为核设施工艺设备研究奠定基础。”
      LIANG Qinglei,LI Jinghuai,LIU Guorong,WANG Bin,ZHOU Hao,TIAN Yuan
      Vol. 47, Issue 3, Article number: 030404(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030404
      摘要:BackgroundThe use of neutron-based methods to locate radioactive sources within sealed containers holds great practical significance.PurposeThis study aims to locate an AmLi source within the detection space of four position-sensitive neutron detectors.MethodsFirst of all, the Monte Carlo method was applied to designing the moderating shield of the detector. Then, a delay circuit was added to one end of the detector hence the position coordinate of the source y-axis (detector axis) was determined according to the time difference between the two ends of the detector to detect the source neutron signal, and the axial position function of each detector was calibrated. Finally, the detector was used to build a measurement space around sealed container, and the position coordinates of the x-axis and z-axis (the other two directions) were determined by the ratio of the neutron count rate of the two adjacent detectors, so was the function calibration. During the measurement of neutron point-source 3D coordinates, the detector with the largest count rate was first selected to determine the axial coordinates of the source, and then the coordinates of the other two directions of the source were determined according to the ratio of the count rate of the two adjacent detectors to the detector, so as to realize the location of the source.ResultsMeasurement results of five different positions of the point source in the detection space show that the positioning deviation on each coordinate axis is within 1.5 cm, and the relative standard deviation of neutrons measured in this detection space is within 1%.ConclusionsThis methodology effectively demonstrated the feasibility of employing neutron position-sensitive detectors to precisely locate radioactive sources, establishing a strong foundation for future endeavors aimed at accurately determining the positions of nuclear materials within processing equipment in nuclear facilities.  
      关键词:Localization;Position-sensitive detector;Point source   
      97
      |
      60
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642000 false
      发布时间:2024-10-25
    • “在核反应堆监测领域,研究人员提出了三种自给能中子探测器信号电流计算方法,精度高,已应用于“华龙一号”反应堆。”
      WU Xiong,ZHANG Xiangju,LUO Shijie,JIANG Jieqiong
      Vol. 47, Issue 3, Article number: 030405(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030405
      摘要:BackgroundSelf-powered neutron detectors (SPNDs) are critical devices in the monitoring and protection systems of nuclear reactors, and their signal current directly reflects the value and distribution of the core power. Insulators play an essential role in the design of SPNDs and are the main factor affecting the calculation accuracy of the signal current.PurposeThis study aims to improve the accuracy of the calculation method of the SPND signal current, ensuring that the measured currents accurately reflect the reactor conditions and meet the highest industrial standards.MethodsFirstly, the signal generation mechanism of the SPND was thoroughly discussed, and three independent calculation methods of the current based on the inherent physical characteristics of the space electric field of an insulator were proposed. Then, high-fidelity simulations of the SPND were performed using the Monte Carlo code, and the three methods were validated based on the simulation results. In addition to the current caused by the neutrons, the current caused by the photons inside the reactor was quantitatively analyzed. Meanwhile, extensive radiation experiments on the various reactors have been performed to verify these three current calculation methods.ResultsThe difference between the results obtained by using the three methods is less than 1%, demonstrating a considerable accuracy. In addition, the current of the rhodium SPND is primarily owing to the neutrons, whereas the photon-induced current is generally less than 5%. Experimental verification results on the several operating reactors show that the difference between the theoretical and experimental results is less than 3%, which also proves its effectiveness and accuracy.ConclusionsThis method has been applied to the large Chinese Gen-III advanced pressurized water reactor (HPR1000) and is universal. It can be used for the signal analysis of different types of SPNDs, as well as for providing valuable references for core monitoring systems in other reactors, such as the Gen-IV fast reactor as well as future fusion reactors.  
      关键词:Self-powered neutron detector;Insulator;Spatial electric field;Signal current;Monte Carlo method   
      102
      |
      49
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642004 false
      发布时间:2024-10-25

      NUCLEAR PHYSICS, INTERDISCIPLINARY RESEARCH

    • “在宇宙元素合成研究中,铕同核异能素152m1Eu的高效激发实现,为控制核能释放提供新途径。”
      LUO Kaijun,FAN Wenru,YUAN Yun,QI Wei,ZHANG Jingli,ZHANG Xiaohui,DENG Zhigang,LUO Wen
      Vol. 47, Issue 3, Article number: 030501(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030501
      摘要:BackgroundNuclear isomers are crucial in cosmic element synthesis and have potential applications in controlling nuclear energy release. Specifically, Europium (Eu) is significant in fundamental studies. For instance, 152Eu is used as a reference source for radioactive experiments, and its isomeric state 152m1Eu has a probability of 73% to produce cosmological p-nuclei 152Gd with β- decay. Therefore, 152m1Eu is a crucial nuclide in the nuclearsynthesis of p-nuclei 152Gd.PurposeThis study aims to realize the efficient excitation of 152m1Eu with a bremsstrahlung source generated by laser plasma.MethodsFirstly, the laser-plasma bremsstrahlung source was utilized to achieve the efficient excitation of 152m1Eu (45.6 keV, T1/2=9.31 h) in the experiment with yields of 8×104 particles/shot by this isotope. Then, numerical simulations of the yield of 152m1, m2Eu were performed using the Geant4-GENBOD program to get generation time, and peak excitation efficiency evolution with electron temperature.ResultsThe results demonstrate that when the electron temperature reaches 15 MeV, the yield of 152m1, m2Eu approaches saturation. When the incident electron charge is 17.6 nC, the yield of 152m1Eu is approximately 8×106 particles/shot, and that of 152m2Eu is approximately 2×105 particles/shot. The generation time of 152m1, m2Eu in the target is approximately 32 ps. When the electron temperature reaches 15 MeV, the peak excitation efficiency of 152m1Eu is expected to be ~1017 particles/s, and that of 152m2Eu is expected to be ~1016 particles/s.ConclusionsThe ultrashort ultrahigh intensity laser technology can significantly enhance the excitation efficiency of isotopes of the same nucleus, and this will provide an important research avenue for the study of cosmic element synthesis and nuclear energy release control applications.  
      关键词:Isomer 152mEu;Bremsstrahlung source;Laser plasma;(γ, n) reaction;Peak excitation efficiency   
      129
      |
      77
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50625735 false
      发布时间:2024-10-25

      NUCLEAR ENERGY SCIENCE AND ENGINEERING

    • “在核反应堆领域,专家推导出瞬时短周期与反应性引入速率约束公式,为控制棒提升速率提供理论依据。”
      ZHU Guifeng,YAN Rui,ZOU Yang,YU Changqing,ZHAO Xuechao,GUO Jian
      Vol. 47, Issue 3, Article number: 030601(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030601
      摘要:BackgroundThe reactor period will dramatically decrease at the beginning of reactivity insertion in the nuclear reactor, which may trigger the protection system of the reactor period and lead to unnecessary shutdown. The instantaneous short reactor period is influenced greatly by the inserting rate of reactivity, but also related with the present delayed neutron precursors, which is difficult to quantify.PurposeThis study aims to explore the relationship between the instantaneous short reactor period and the inserting rate of reactivity from a theoretical perspective.MethodsA point reactor model was used to deduce the inserting rate of the reactivity function using the variable factors of reactivity, reactor period, and reactor dynamic parameters, with some conservative assumptions to omit the effect of delayed neutron precursors. The relationship between reactivity insertion rate and transient period of reactor was derived after analysis on the short period phenomenon. Then, the formula of relationship was verified for several transient cases.ResultsThe results show that the reactor periods are all larger than the aim reactor periods for all transient cases when using the rate constraint of reactivity insertion in the aforementioned formula. According to the proposed theoretical framework, unnecessary shutdown during an instantaneous short reactor period can be avoided.ConclusionsA theoretical framework proposed in this study can be applied to the control of rod withdrawal rate during the operation of nuclear reactors.  
      关键词:Nuclear reactor;Reactor period;Transient state;Reactivity   
      368
      |
      53
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50500136 false
      发布时间:2024-10-25
    • “在小型反应堆领域,基于自然循环的非能动余热排出系统研究取得进展,专家用RELAP5程序对中间回路运行特性进行计算分析,为小型堆非能动系统研究提供应用价值。”
      DONG Botong,XIAO Yao,LI Junlong,XU Ziyi,LIU Maolong,LIU Limin,FU Junsen,GU Hanyang
      Vol. 47, Issue 3, Article number: 030602(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030602
      摘要:BackgroundPassive residual heat-removal system (PRHRS) based on natural circulation has been widely used in small reactors connected on secondary side loop.PurposeThis study aims to develop and analyze a passive residual heat-removal system on the secondary side of a small reactor to improve reactor safety.MethodsBased on the completed heat-transfer experiment of the intermediate circuit of a small integrated nuclear power plant, Reactor Excursion and Leak Analysis Program (RELAP) was employed to determine and analyze the natural circulation characteristics of the intermediate loop were determined and analyzed.ResultsThe heat transfer rate results of the program are in good agreement with the experimental data, and the natural cycle characteristics of PRHRS can be characterized. The pressure of the system loop is determined by the average temperature of the primary side of the steam generator (SG), and the difference in the inlet temperature of the SG primary side, mass flow rate, and height of the cooling and heating sources significantly influence the heat-transfer performance of the SG system. The heat-transfer performance of the waste-heat-removal system is more sensitive to the resistance of the system loop when the temperature of the primary-side inlet of the SG is higher.ConclusionsThese results provide a valuable application for further investigations of passive systems in small reactors.  
      关键词:Small reactor;Natural circulation;Passive;Residual heat-removal system;RELAP5   
      112
      |
      55
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50510953 false
      发布时间:2024-10-25
    • “在钍基熔盐反应堆领域,研究人员建立了快速分析氟锂铀和氟锂钍中锂、铀和钍含量的方法,操作简便,测定结果准确,适合大批量样品分析。”
      HAN Ling,TANG Yuanyuan,GE Min,QIAN Yuan,LIU Hongtao
      Vol. 47, Issue 3, Article number: 030603(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030603
      摘要:BackgroundLiF-UF4 and LiF-ThF4 are used as addition salts in thorium-based molten salt nuclear reactors. Monitoring the product quality during the preparation of molten salts necessitates the analysis of the contents of the main metal elements in LiF-UF4 and LiF-ThF4, namely, lithium, uranium, and thorium.PurposeThis study aims to establish effective, rapid analysis methods for determination of primary metal elements in LiF-UF4 and LiF-ThF4 molten salts.MethodsFirstly, the LiF-UF4 samples were treated with nitric acid and hydrogen peroxide whilst the LiF-ThF4 samples were dissolved in aluminum nitrate. Then, inductively coupled plasma atomic emission spectrometry was used as rapid analysis methods for measuring these two molten salts, and manganese was employed as the internal standard element to reduce the effect of signal drift.ResultsIn the analytical method of LiF-UF4, the recoveries of Li and U are detected to be 99.6%~102.4% and 99.6%~101.8%, respectively. The relative standard deviations (RSDs) of Li and U are 0.2%~0.7%, and 1.1%~2.0%, respectively. In the analytical method of LiF-ThF4, the recoveries of Li and Th are detected to be 99.6%~102.3% and 99.6%~102.4%, respectively. The relative standard deviations of Li and Th are 1.9%~2.0%, and 0.3%~0.4%, respectively.ConclusionsThe proposed methods are simple, time-efficient, accurate, and suitable for rapid analyses of large numbers of samples.  
      关键词:LiF-UF4;LiF-ThF4;ICP-AES;Lithium;Uranium;Thorium   
      99
      |
      42
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642288 false
      发布时间:2024-10-25
    • “在核动力破冰船领域,专家分析了小型棒控压水堆控制棒布置与动作策略,为准确计算堆芯寿期提供解决方案。”
      WU Zhiqiang,XIE Jinsen,LOU Lei,CHEN Pengyu,LIU Tao,DENG Nianbiao,YU Tao
      Vol. 47, Issue 3, Article number: 030604(2024) DOI: 10.11889/j.0253-3219.2024.hjs.47.030604
      摘要:BackgroundSmall rod-controlled pressurized water reactors have foregone the use of soluble boron and heavily rely on control rods and burnable poison rods for reactor control.PurposeThis study aims to explore the influence of control rods on the key performance metrics of a long-term small rod-controlled pressurized water reactor.MethodsFirst, a KLT-40 reactor used for nuclear icebreakers was taken as research object, and a critical rod position-search burnup code was developed based on OpenMC. Then, the core lifetime and other indicators such as the axial power offset, fuel utilization, and radial power peak factor, were compared between with and without the designed control rods for the design and analysis of the control rod layout of KLT-40 reactor. Finally, the influence of different move-in/out strategies on axial power offset was analyzed.ResultsThe core lifetime can be extended from 590 effective full power days (EFPDs) to 650~698 EFPDs with the designed control rods. Adopting a strategy of prioritizing the movement of low-value rod groups effectively reduces the axial power offset, with values of -0.69 and +0.8 decreasing to -0.29 and +0.52, respectively.ConclusionsThe control rod burnup calculation strategy adopted to accurately calculate the core lifetime of small rod-controlled pressurized water reactors can effectively reduce the axial power offset by using a reasonable move-in/out strategy.  
      关键词:Long-term PWR;Control rod design;Control rod move-in/out strategies;Core lifetime;Power distribution   
      139
      |
      57
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 50642143 false
      发布时间:2024-10-25
    0