最新刊期

    卷 0 , 期 0 , 2020
    • Wang Guangyu
      Issue 8, (1991)
      摘要:The influence of electron beams on heat dissipation in an electron linac has been studied. The temperature responses for different electron beams in the linac are calculated.The suitable moment for inputting electron beam after the start of the linac is given. These results may provide a reference to the design and operation of a linac.  
        
      13
      |
      40
      |
      2
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933764 false
      发布时间:2021-04-20
    • Cai Wei Liang Guozhao Qian Xing Dai Guangxi
      Issue 8, (1991)
      摘要:The textual work is to design, and test a time zero device with domestic micrcchannel plates in which the signal is gained. An optimal overall time resolution of 183ps(FWHM) is obtained for a ThC’ α-particle source. The relationship between cetection efficiency of the time zero detector and other variable is discussed in. detail.  
        
      8
      |
      29
      |
      1
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933879 false
      发布时间:2021-04-20
    • Wang Lirzhou Wang Yunyong Xu Zhijing Zhao Jinpei
      Issue 8, (1991)
      摘要:For the gas system of shower counter used in Beijing Spectrometer(BES), the principles of design, the selection of suitable materials, and the influence of undesirable impurities in gas on the detector are discussed. The principle of operation, cleaning and installation, and leak detection of the gas system are also described.  
        
      8
      |
      24
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933912 false
      发布时间:2021-04-20
    • Shen Ji Wang Honghua Han RongdianYe Yunxiu Weng Huimin Shi Guoshun
      Issue 8, (1991)
      摘要:A iron-free double focusing β-spectrometer was repaired. Some important improvements were made, including adding a single-board microcomputer system to control the spectro meter. The inner conversion e’ectron spectrum of 170Tm was measured to check its perfor-m nce.  
        
      9
      |
      39
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933859 false
      发布时间:2021-04-20
    • Qian Qinfang Chao Zhiyu Wu Yingrong Tian Jibing
      Issue 8, (1991)
      摘要:Trace elements Fe, Zn and Ca in hair samples taken from four athletes have been de-termined by using SR X-ray fluorescence analysis technique. Each sample is scanned point by point at 1.5mm of interval, which corresponds to 5 days of hair growth. Preliminary results show that the change of iron content in hair is related to exercise capacity of athletes, but no observable change is found for Zn and Ca content. It is verified that sport is one of the causes leading to iron deficiency of athletes.  
        
      9
      |
      100
      |
      8
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933936 false
      发布时间:2021-04-20
    • Lei Xiangguo Guo Yingxiang Sun Xiangfu Luo YixiaoWang Jicheng Yu Jianfang
      Issue 8, (1991)
      摘要:A tiny Lanzhou crystal ball consists of 14 hexagonal prism BGO detector units. The assembly technique and performance of the BGO units are presented. Responses of the ball for sum energy and multiplicity of cascade γ-rays have been simulated by the coincidence of two cascade γ rays of a 60Co source and the multi-parameter acquisition technique.  
        
      8
      |
      30
      |
      2
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933947 false
      发布时间:2021-04-20
    • Cheng Yingfang
      Issue 8, (1991)
      摘要:A gravimetric method for measuring crystal water in uranium tetrafluoride is reported. Peing convenient, reliable and quick, it can be used as a rcutir.e analytical method to measure crystal water in uranium, thorium tetrafluoride etc.  
        
      8
      |
      85
      |
      0
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933905 false
      发布时间:2021-04-20
    • Liu Xianyi Chen Faju Song Xuehua Guo Dazhi
      Issue 8, (1991)
      摘要:Attempt was made to determine progesterone in hair using competitive protein-binding assay for pregnancy diagnosis of dairy cows. The average accuracy of pregnancy diagnosis in 475 cows was 86.2% for pregnant cows and 96.69% for non-pregnant cows repectively when hair samples were taken on the 24th day after artificial insemination and clipped at the udder of the animals.  
        
      8
      |
      40
      |
      3
      <HTML>
      <L-PDF><Meta-XML>
      <引用本文> <批量引用> 8933892 false
      发布时间:2021-04-20
    0