Natural circulation characteristics of main loop after shutdown of liquid-fuel molten salt reactor
NUCLEAR ENERGY SCIENCE AND ENGINEERING|更新时间:2024-10-25
|
Natural circulation characteristics of main loop after shutdown of liquid-fuel molten salt reactor
“In the field of liquid fuel molten salt reactors, experts have established a passive waste heat removal loop natural circulation model, analyzed the effects of molten salt properties, loop structure, and equipment resistance coefficient on heat removal capacity, and provided solutions to improve waste heat removal capacity.”
XUE Shuaiyu, male, born in 1996, graduated from Nanjing University of Aeronautics and Astronautics in 2019, doctoral student, focusing on nuclear reactor thermal hydraulics
ZHOU Chong, E-mail: zhouchong@sinap.ac.cn
基金信息:
the National Key Research and Development Program of China(2020YFB1902000);the "Strategic Priority Project" of Chinese Academy of Sciences(XDA0201002;XDA22010501);Shanghai Pilot Program for Basic Research–Chinese Academy of Sciences, Shanghai Branch(JCYJ-SHFY-2021-003);Shanghai Institute of Applied Physics, Chinese Academy of Sciences, "Research on Core Modularization Theory and Comparison"(SINAP-QYJS-202202)
XUE Shuaiyu,ZHOU Chong,ZOU Yang,et al.Natural circulation characteristics of main loop after shutdown of , liquid-fuel molten salt reactor[J].NUCLEAR TECHNIQUES,2024,47(07):070604-070604.
XUE Shuaiyu,ZHOU Chong,ZOU Yang,et al.Natural circulation characteristics of main loop after shutdown of , liquid-fuel molten salt reactor[J].NUCLEAR TECHNIQUES,2024,47(07):070604-070604. DOI: 10.11889/j.0253-3219.2024.hjs.47.070604.