您当前的位置:
首页 >
文章列表页 >
Study on spectrum stabilization technique for a portable LaBr3(Ce) gamma spectrometer
NUCLEAR ELECTRONICS AND INSTRUMENTATION | 更新时间:2024-10-25
    • Study on spectrum stabilization technique for a portable LaBr3(Ce) gamma spectrometer

    • “In the field of gamma spectroscopy analysis, scientists have developed a portable gamma spectrometer stabilization technique based on LaBr3 (Ce) detector, effectively suppressing the "spectral line drift" caused by environmental changes in the detector. This technology utilizes the 36 keV characteristic peak in the detector's own background spectrum and the 1460 keV characteristic peak in the natural background spectrum at 40K as stable spectrum reference peaks. A custom spectral correlation formula is used to measure the correlation between the measured energy spectrum and the standard background spectrum, and a method is proposed to combine the correlation between the reference peak and the energy spectrum for stable spectrum. The experimental results show that within the temperature range of -30~50 ℃, this stable spectrum method does not require pre calibration of the relationship curve between the reference peak and temperature, and can effectively prevent the occurrence of erroneous stable spectra in the presence of interfering nuclides. In addition, it ensures that the peak drift of the reference peak is stable within ± 1 channel in the case of sudden changes in temperature rate exceeding 50 ℃ ⋅ h-1.”
    • NUCLEAR TECHNIQUES   Vol. 44, Issue 4, Article number: 040401(2021)
    • DOI:10.11889/j.0253-3219.2021.hjs.44.040401    

      CLC: TL81
    • Received:29 December 2020,

      Revised:20 February 2021,

      Published:15 April 2021

    移动端阅览

  • CHEN Chen,WU Huan.Study on spectrum stabilization technique for a portable LaBr3(Ce) gamma spectrometer[J].NUCLEAR TECHNIQUES,2021,44(04):43-50. DOI: 10.11889/j.0253-3219.2021.hjs.44.040401.

  •  
  •  

0

Views

50

下载量

1

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

Simulation study on the factors affecting the detection efficiency of a LaBr3(Ce) detector
The spectrum stabilization study on the 13N monitoring instrument
A natural gamma-ray spectrometer for well logging

Related Author

ZHANG Yuzhong
YU Ziqiao
SHU Shuangbao
CHEN Jingjing
CHEN Zhiqiang
LANG Xianli
凌球
QU Guopu LING Qiu GUO Lanying ZHAO Lihong CHEN Jianzhen CHEN Conggui

Related Institution

School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology
College of Nuclear Science and Technology, Nanhua University
南华大学 核科学技术学院
Shanghai Institute of Nuclear Research, Academia Sinica
0