Monte Carlo simulation of the influence of medical foam on particle dose
NUCLEAR CHEMISTRY, RADIOCHEMISTRY, RADIOPHARMACEUTICALS AND NUCLEAR MEDICINE|更新时间:2024-10-25
|
Monte Carlo simulation of the influence of medical foam on particle dose
“In the field of radiotherapy localization, new progress has been made in the study of the effect of foam gel on accelerator dose. Experts used Monte Carlo programming to model and calculate the effects of different thicknesses of foam adhesive on particle dosage, providing reference for clinical use.”
NUCLEAR TECHNIQUESVol. 43, Issue 9, (2020)
作者机构:
1.成都理工大学 成都 610000
2.重庆医科大学附属第二医院 重庆 400010
作者简介:
XIAO Yang, male, born in 1992, graduated from Chengdu University of Technology in 2016, master student, focusing on accelerator technology
XIAO Yang,ZHANG Qingxian.Monte Carlo simulation of the influence of medical foam on particle dose[J].NUCLEAR TECHNIQUES,2020,43(09):19-26. DOI: 10.11889/j.0253-3219.2020.hjs.43.090302.
Monte Carlo simulation of the influence of medical foam on particle dose