Research on optimum detection angle and switching point of non-radioactive nuclear ash bucket level meter
NUCLEAR ELECTRONICS AND INSTRUMENTATION|更新时间:2024-10-25
|
Research on optimum detection angle and switching point of non-radioactive nuclear ash bucket level meter
NUCLEAR TECHNIQUESVol. 42, Issue 10, (2019)
作者机构:
1.河北北方学院 张家口 075000
2.北京大学 昌平校区管理办公室 北京 102249
3.成都理工大学 成都 610000
作者简介:
XIE Xicheng, female, born in 1988, graduated from Chengdu University of Technology with a doctoral degree in 2015, focusing on nuclear technology and applications
XIE Xicheng,ZHANG Yuanyuan,GUO Yajuan,et al.Research on optimum detection angle and switching point of non-radioactive nuclear ash bucket level meter[J].NUCLEAR TECHNIQUES,2019,42(10):33-38.
Material level detection is a very important issue for the automatic control of thermal power. How to monitor the material and powder level has become an urgent problem for the thermal power plant.
Purpose
2
This study aims to find out the best detection angle and switching point to provide theoretical guidance for instrument development and sensitivity improvement.
Methods
2
First of all
Monte Carlo simulation was applied to the optimum design of the best detection angle for non-radioactive nuclear ash hopper level meter in the range of 0°~90°. Then the angle between the ash bucket wall and the horizontal plane for the optimum detection angle was determinated. Finally
a complete model of dust hopper and passive nuclear level gauge for electrostatic precipitator (ESP) was established
and the high and low switch points material level were by "second derivative method".
Results
2
When the angle between the probe and the horizontal line reaches 30°
the maximum energy flux is detected while the angle between the ash bucket wall and the horizontal plane is 61.224°. The absorption dose rate curve of material level meter with different fly ash height at 30° detection angle is obtained.
Conclusions
2
This study provides theoretical guidance for the development of non-radioactive nuclear ash hopper level meter instrument and improvement of sensitivity in thermal power plants.
ZHOU Shijie . Selection of material level meter in thermal power plant and application of passive nuclear material level meter [J ] . Industrial Instruments and Automation Devices , 2013 , ( 3 ): 86 - 88 . DOI: 10.3969/j.issn.1000-0682.2013.06.026 http://dx.doi.org/10.3969/j.issn.1000-0682.2013.06.026 .
GAI Xinhua , CHEN Zhaoxian , LI Jianrong . Application of a new non-contact radioactive source nuclear level meter [J ] . East China Electric Power , 2009 , ( 11 ): 1948 - 1950 .
LI Wenyuan , XING Futang . The feasibility of using CFX to simulate the unloading process of ash hopper [J ] . Industrial Safety and Environmental Protection , 2012 , ( 7 ): 20 - 21 .
REN Yanming . Application of nuclear level meter without radiation source in thermal power plant [J ] . Shanxi Electric Power , 2008 , ( 6 ): 42 - 43 .
ZHAO Aiming , WANG Xuan , REN Bin , et al . Research on the nuclear level meter without radioactive source [J ] . Nuclear Electronics and Detection Technology , 2013 , ( 2 ): 211 - 216 .
YUAN Chunlin , ZHANG Jinming , DUAN Jiuxiang , et al . Chemical composition characteristics of fly ash from thermal power plants in China [J ] . Environmental Protection of Electric Power , 1988 , ( 3 ): 9 - 14 .
Nisnevich M , Sirotin G , Schlesinger T , et al . Radiological safety aspects of utilizing coal ashes for production of lightweight concrete [J ] . Fuel , 2008 , ( 87 ): 1610 - 1616 .
JIA Xiaodan , LU Xinwei . Natural radioactivity level in raw coal and fly ash of baoji coal-fired power plant [J ] . Radiation Protection , 2006 , ( 5 ): 310 - 313 .
Palomba M , Erasmo G D , Pantaleo A . An application of the CSSE code-analysis of pulse pile-up in NaI(Tl) detectors used for TNA [J ] . Nuclear Instruments and Methods in Physics Research , 2003 , ( 498 ): 397 - 414 .