“In the field of nuclear power safety, experts have established a million kilowatt level PWR nuclear power unit model based on the MAAP4.0.3 program, studied the serious accident process of heat pipe rupture accident combined with safety injection failure, and explored effective mitigation measures. The research results indicate that the larger the rupture area, the earlier the pressure vessel fails, and the greater the hydrogen production during MCCI process; Early deployment of the safety injection system can effectively alleviate the process of accidents and prevent pressure vessel failure.”
NUCLEAR TECHNIQUESVol. 42, Issue 2, (2019)
作者机构:
1.南华大学 核科学与技术学院 衡阳 421001
2.核能与核技术工程虚拟仿真实验教学中心 衡阳 421001
作者简介:
LIU Peiqi, female, born in 1995, graduated from China Three Gorges University in 2016, master student, focusing on reactor thermal hydraulic design and accident safety analysis
YU Tao, E-mail: yutao29@sina.com
基金信息:
National Defense Technology Industry Nuclear Power Technology Innovation Center Project(HDLCXZX-2017-HD-017);Provincial Innovation Foundation For Postgraduate(CX2018B610);University of South China Innovation Foundation for Postgraduate(2018KYZ006)
LIU Peiqi,ZHAO Pengcheng,YU Tao,et al.Analysis of LOCA with different break sizes in PWR[J].NUCLEAR TECHNIQUES,2019,42(02):68-75. DOI: 10.11889/j.0253-3219.2019.hjs.42.020601.