National Natural Science Foundation of China;the National Key Research and Development Program of China;Fundamental Research Funds for the Central Universities;Fundamental Research Funds for the Central Universities;Teaching Reform Project for China University of Petroleum;National Science and Technology Major Project;Science and Technology Plan Project of Shandong Education of China
Yue ZHOU, Huawei YU, Xianghong CHEN, et al. Study on near detector-source spacing of density logging based on X-ray source[J]. Nuclear techniques, 2018, 41(12): 120401
DOI:
Yue ZHOU, Huawei YU, Xianghong CHEN, et al. Study on near detector-source spacing of density logging based on X-ray source[J]. Nuclear techniques, 2018, 41(12): 120401 DOI: 10.11889/j.0253-3219.2018.hjs.41.120401.
Study on near detector-source spacing of density logging based on X-ray source
It has become a new trend to use X-ray source instead of
137
Cs source in density logging for development of oil logging.
Purpose
2
This study aims to analyze the near detector-source spacing's change when using a lower energy X-ray source instead of
137
Cs source in density logging.
Methods
2
Monte Carlo simulation method is used to study the critical detector-source spacing of different energy X-ray sources during the formation of water saturated limestone with different porosity
in addition
the near detector-source spacing is analyzed according to those sensitivities of X-ray sources and
137
Cs source.
Results
2
Simulation results show that low energy X-ray source's critical detector-source spacing is shorter compared with
137
Cs source's density instrument. When the density sensitivity is the same
the near detector-source spacing of X-ray source is shorter than that of
137
Cs source.
Conclusion
2
This study provides a theoretical basis for the design of near detector-source spacing of instrument.
关键词
Keywords
references
Evans M. Accelerator-based methods and apparatus for measurement while drilling[P]. Unite States: 5539225 patent. 1997-08-20.
Huawei YU , Jianmeng SUN , Wenjuan ZHU , . Monte-Carlo simulation method in pulsed neutron density logging while drilling . Well Logging Technology , 2009 . 33 ( 6 ): 521 - 524 . DOI: 10.3969/j.issn.1004-1338.2009.06.005 http://doi.org/10.3969/j.issn.1004-1338.2009.06.005 .
A J Becker , J R Boyce , G W Corris , . Detection of scattered X-rays from an electrom linic in a borehole . Nuclear Instruments and Methods in Physics Research , 1987 . B24/25 995 - 998 .
Wraight P, Becker A J, Groves J L. High voltage X-ray generator and related oil well formation analysis[P]. Unite States: 0274276 patent. 2009-11-05.
Simon M, Tkabladze A, Beekman S, et al . A revolutionary X-ray tool for true sourceless density logging with soperior performance[C]. London, UK: SPWLA 59th Annual Logging Symposium, 2018.
黄 隆基 . 核测井原理 , : 东营 石油大学出版社 , 2000 .
Longji HUANG . Nuclear logging principle , : Dongying University of Petroleum Press , 2000 .