浏览全部资源
扫码关注微信
1.中国科学院上海应用物理研究所 张江园区 上海 201204
2.中国科学院大学 北京 100049
3.上海科技大学 物质科学与技术学院 上海 200031
Received:28 February 2017,
Revised:22 March 2017,
Published:10 June 2017
移动端阅览
Yiqi HUANG, Bin LI. Customized human eye modelling and refractive surgery along with vision quality assessment[J]. Nuclear techniques, 2017, 40(6): 060501
Yiqi HUANG, Bin LI. Customized human eye modelling and refractive surgery along with vision quality assessment[J]. Nuclear techniques, 2017, 40(6): 060501 DOI: 10.11889/j.0253-3219.2017.hjs.40.060501.
人眼是一台精巧而复杂的光学成像系统,其复合结构存在像差,它的空间极限分辨能力要小于无像差的同口径的小孔所对应的衍射极限。眼球也并非完美对称的,各介质曲面由于不规则性或位置异常等因素对视觉质量产生影响,为精确修正眼球的屈光不正带来困难。而常规的角膜手术虽然可以较好地修正以离焦为主的低阶像差,但却不能改善高阶像差,在手术实施的过程中反而会因为改变角膜的面型因子,引入较大的球差,严重影响暗视场的视力。本文依据人眼的基本结构及统计的典型人眼参数,实现全眼球数字化模拟并考虑了个性化因子,分析影响视力的主要因素,针对眼球屈光不正设计出个性化的角膜手术方案,使术后眼球的像差得到全面修正,从而实现最佳的人眼成像能力。
Background
2
Human eye is a complex and delicate imaging system
whose intrinsic optical aberrations limit the ultimate spatial resolution
making it worse than the diffraction limit of an aberration-free aperture in equal-size. Especially the asymmetry and irregularity presence in various components of eyeball would prevent the precise eye-surgery from achieving superb imaging quality. The conventional eye surgery could well correct the low-order optical aberrations dominant by "defocus"
however make no rectification for the high-order aberrations. Meanwhile it would modify the original corneal a-sphericity to introduce significant "spherical aberration" to the eye-ball
which causes the severe reduction of vision acuity
especially at the dark environment.
Purpose
2
In order to rectify the post-surgery visual quality reduction due to dimer environment
as well as the side-effects e.g. halo
dizziness
we proposed a personalized eye-modelling and surgery scheme
and compared the post-surgery outcomes to the conventional ones.
Methods
2
We established a personalized eye model at the regular myopia of (-2D or -5D)
and compared the post-surgery imaging quality of the conventional or customized corneal ablation schemes implementing three typical techniques in optometry:the ray-tracing spot diagrams at fovea
the modulation transfer function of the spot diagrams
and the wave-front aberration distributions of the eye-ball.
Results
2
We find out that the traditional refractive surgery has many limitations
it can't correct the intraocular astigmatism and the high order aberrations either
while the customized eye surgery is able to reduce the various orders of the optical aberrations in general nicely to achieve the much better imaging quality.
Conclusion
2
The techniques we use for assessing the imaging quality and spatial resolution at retina are objective
which clearly demonstrate the personalized eye-modelling and the ablation surgery schemes based on that achieved remarkable advantages to approach the retina resolution.
Millodot M. Dictionary of optometry and visual science[M]. Elsevier Health Sciences, 2014.
D Z Reinstein , T J Archer , M Gobbe . The history of LASIK . Journal of Refractive Surgery , 2012 . 28 ( 4 ): 291 - 298 . DOI: 10.3928/1081597X-20120229-01 http://doi.org/10.3928/1081597X-20120229-01 .
R Scott , T Grosvenor . Structural model for emmetropic and myopic eyes . Ophthalmic & Physiological Optics , 1993 . 13 ( 1 ): 41 - 47 .
C R Munnerlyn , S J Koons , J Marshall . Photorefractive keratectomy:a technique for laser refractive surgery . Journal of Cataract & Refractive Surgery , 1988 . 14 ( 1 ): 46 - 52 . https://www.researchgate.net/publication/19815862_Photorefractive_keratectomy_A_technique_for_laser_refractive_surgery .
A Tawfik , A M Eid , R Hasanen , . Q -value customized ablation (custom- Q ) versus wavefront optimized ablation for primary myopia and myopic astigmatism . International Ophthalmology , 2014 . 34 ( 2 ): 259 - 262 . DOI: 10.1007/s10792-013-9828-1 http://doi.org/10.1007/s10792-013-9828-1 .
于 秋菊 , 张 海东 , 张 永红 . 飞秒激光辅助 Q 值调整的非球面个性化LASIK与常规LASIK术后视觉质量对比研究 . 中国实用眼科杂志 , 2016 . 34 ( 3 ): 258 - 262 . DOI: 10.3760/cma.j.issn.1006-4443.2016.03.013 http://doi.org/10.3760/cma.j.issn.1006-4443.2016.03.013 .
C Villa , R Gutierrez , J Jimenez , . Night vision disturbances after successful LASIK surgery . British Journal of Ophthalmology , 2007 . 91 ( 8 ): 1031 - 1037 . DOI: 10.1136/bjo.2006.110874 http://doi.org/10.1136/bjo.2006.110874 .
J S Kung , E E Manche . Quality of vision after wavefront-guided or wavefront-optimized LASIK:a prospective randomized contralateral eye study . Journal of Refractive Surgery , 2016 . 32 ( 4 ): 230 - 236 . DOI: 10.3928/1081597X-20151230-01 http://doi.org/10.3928/1081597X-20151230-01 .
H L Liou , N A Brennan . Anatomically accurate, finite model eye for optical modeling . Journal of the Optical Society of America A , 1997 . 14 ( 8 ): 1684 - 1695 . DOI: 10.1364/JOSAA.14.001684 http://doi.org/10.1364/JOSAA.14.001684 .
D A Atchison . Optical models for human myopic eyes . Vision Research , 2006 . 46 ( 14 ): 2236 - 2250 . DOI: 10.1016/j.visres.2006.01.004 http://doi.org/10.1016/j.visres.2006.01.004 .
R Navarro , J Santamaría , J Bescós . Accommodation-dependent model of the human eye with aspherics . Journal of the Optical Society of America A , 1985 . 2 ( 8 ): 1273 - 1280 . DOI: 10.1364/JOSAA.2.001273 http://doi.org/10.1364/JOSAA.2.001273 .
H Masalehdan , E Lotfi , A Lotfi , . Modeling of Zernike optical aberrations by MTF and PSF . Biomedical Optics Express , 2010 . 18 ( 5 ): 5245 - 5248 . DOI: 10.1364/OE.18.005245 http://doi.org/10.1364/OE.18.005245 .
D A Atchison , S B George . Optics of the human eye , : Oxford Butterworth , 2000 .
王 雁 . 波前像差与临床视觉矫正 , : 北京 人民卫生出版社 , 2011 .
王 洁梅 . 基于Zernike多项式的波前像差研究 . 现代计算机 , 2014 . ( 2 ): 46 - 49 . DOI: 10.3969/j.issn.1007-1423(z).2014.02.012 http://doi.org/10.3969/j.issn.1007-1423(z).2014.02.012 .
Jiemei WANG . Research on wavefront aberration based on Zernike polynomials . Modern Computer , 2014 . ( 2 ): 46 - 49 . DOI: 10.3969/j.issn.1007-1423(z).2014.02.012 http://doi.org/10.3969/j.issn.1007-1423(z).2014.02.012 .
0
Views
25
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621