

浏览全部资源
扫码关注微信
1.西南民族大学 电气信息工程学院 成都 610041
2.防化研究院 第二研究所 北京 102205
Received:29 April 2016,
Revised:10 June 2016,
Published:2016-09
移动端阅览
Yingrui HU, Xiaoqiang LI. Design and implementation of radioactivity identifying pedestrian portal[J]. Nuclear techniques, 2016, 39(9): 090403
Yingrui HU, Xiaoqiang LI. Design and implementation of radioactivity identifying pedestrian portal[J]. Nuclear techniques, 2016, 39(9): 090403 DOI: 10.11889/j.0253-3219.2016.hjs.39.090403.
为保护重要场所区域安全,提升防止携带特殊核材料或脏弹等引起的核恐怖威胁的能力,研制了行人放射性快速识别仪。该识别仪由NaI探测器和单片嵌入式现场可编程门阵列(Field Programmable Gate Array
FPGA)组成,采用数字梯形滤波成形技术和幅度谱数据处理优化实现方法,能够在1s内实现γ辐射探测、同位素识别及自动分类。在662 keV处能量分辨率为7.44%,在距离探测器中心点1m处,置信度99%条件下,最低可探测活度41.9kBq,对5类
137
Cs放射源能实现可靠报警,性能达到国外同类产品水平。
Background
2
The SPIR-IDENT(Site Protection Against Intrusion of Radioactive Material)advance spectroscopic pedestrian portal released by MGP company in recent years could detect and identify actual radiological threats in real time
but no similar domestic product with independent property rights exists in China at present.
Purpose
2
This study aims to develop a radioactivity identifying pedestrian portal with independent property rights to enhance the ability of protection against radiological threats
such as intrusion of special nuclear materials or radiological dispersion devices into critical infrastructure.
Methods
2
A 2-L NaI detector is employed to connect with a large scale Field Programmable Gate Array(FPGA)based digital processing system.Digital trapezoidal filter
spectroscopy processing block including spectroscopy composition
smoothing and peak-seeking were implemented in a single FPGA
and a μC/OS-Ⅱ soft-core was imported to perform digital spectroscopy stabilization
nuclide identification and classification in this FPGA.The spectra processing method was optimized by using hardware multiplier and hardware divider to improve the algorithm speed to satisfy the system requirement.
Results
2
Experimental test shows that the radioactivity identifying pedestrian portal can detect and discriminate radioactive at the distance of less than 1m from the center point of detector within 1 s.The energy resolution is 7.44% @662 keV and the minimum detectable activity is 41.9 kBq.
Conclusion
2
With the large scale embedded FPGA technology and the nuclear pulse digitized processing and shaping technology
a bulk volume NaI detector can be used to implement an effective radioactivity identifying pedestrian portal.
肖无云, 梁卫平, 赵建兴, 等.数字化核脉冲测量技术及其应用探讨[C].第十四届全国核电子学与探测技术学术年会论文集, 北京:中国科学会, 2008 http://cpfd.cnki.com.cn/article/cpfdtotal-hdzx200807001033.htm
XIAO Wuyun, LIANG Weiping, ZHAO Jianxing, et al.Discussion on digital nuclear pulse measuring techniques and their applications[C].Proceedings of the 14th National Conference on Nuclear Electronics & Detection Technology, Beijing:Chinese Nuclear Society, 2008
陈亮.核素识别算法及数字化能谱采集系统研究[D].北京:清华大学, 2009 http://www.oalib.com/references/18716730
CHEN Liang.Research on the nuclide identification algorithm and digital spectra acquisition system[D].Beijing:Tsinghua University, 2009
胡 颖睿 , 肖 无云 , 梁 卫平 , . 基于嵌入式FPGA的数字化便携式LaBr3(Ce) γ谱仪 . 核电子学与探测技术 , 2013 . 38 ( 8 ): 928 - 931 . DOI: 10.3969/j.issn.0258-0934.2013.08.004 http://doi.org/10.3969/j.issn.0258-0934.2013.08.004 .
Xiaomeng CHEN , Yuzhong ZHANG , Xianyun AI , . Method of digital Dither adding for digital multi-channel pulse amplitude analyzer . Nuclear Techniques , 2015 . 38 ( 5 ): 050401 DOI: 10.3969/j.issn.0258-0934.2013.08.004 http://doi.org/10.3969/j.issn.0258-0934.2013.08.004 .
陈 小猛 , 张 羽中 , 艾 宪芸 , . 数字多道脉冲幅度分析器中数字Dither加入方法 . 核技术 , 2015 . 38 ( 5 ): 050401 DOI: 10.11889/j.0253-3219.2015.hjs.38.050401 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.050401 .
Xiaomeng CHEN , Yuzhong ZHANG , Xianyun AI , . Method of digital Dither adding for digital multi-channel pulse amplitude analyzer . Nuclear Techniques , 2015 . 38 ( 5 ): 050401 DOI: 10.11889/j.0253-3219.2015.hjs.38.050401 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.050401 .
焦 仓文 , 邓 明 , 陆 士立 , . 小口径γ能谱测井仪研制 . 核技术 , 2015 . 38 ( 4 ): 040403 DOI: 10.11889/j.0253-3219.2015.hjs.38.040403 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.040403 .
Cangwen JIAO , Ming DENG , Shili LU , . Research and development of slim borehole gamma ray spectrometry logger . Nuclear Techniques , 2015 . 38 ( 4 ): 040403 DOI: 10.11889/j.0253-3219.2015.hjs.38.040403 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.040403 .
梁 卫平 , 胡 颖睿 , 肖 无云 , . 数字化多道脉冲幅度分析器调理电路设计 . 核电子学与探测技术 , 2012 . 32 ( 4 ): 462 - 465 . DOI: 10.3969/j.issn.0258-0934.2012.04.021 http://doi.org/10.3969/j.issn.0258-0934.2012.04.021 .
Weiping LIANG , Yingrui HU , Wuyun XIAO , . Digital multi-channel pulse height analyze pre-filter circuit design . Nuclear Electronics & Detection Technology , 2012 . 32 ( 4 ): 462 - 465 . DOI: 10.3969/j.issn.0258-0934.2012.04.021 http://doi.org/10.3969/j.issn.0258-0934.2012.04.021 .
肖 无云 , 梁 卫平 , 邵 建辉 , . 基于FPGA的数字化核脉冲幅度分析器 . 核电子学与探测技术 , 2008 . 28 ( 6 ): 1069 - 1071 . DOI: 10.3969/j.issn.0258-0934.2008.06.006 http://doi.org/10.3969/j.issn.0258-0934.2008.06.006 .
Wuyun XIAO , Weiping LIANG , Jianhui SHAO , . Digital multi-channel nuclear pulse height analyzer on FPGA . Nuclear Electronics & Detection Technology , 2008 . 28 ( 6 ): 1069 - 1071 . DOI: 10.3969/j.issn.0258-0934.2008.06.006 http://doi.org/10.3969/j.issn.0258-0934.2008.06.006 .
F Glenn . Radiation detection and measurement . New York:John Wiley & Sons, Inc , 2010 . DOI: 10.3969/j.issn.0258-0934.2008.06.006 http://doi.org/10.3969/j.issn.0258-0934.2008.06.006 .
安然.基于FPGA的除法器的设计和实现[D].成都:成都理工大学, 2011
AN Ran.The design and implementation of divider unit based on FPGA[D].Chengdu:Chengdu University of Technology, 2011
凌 球 , 郭 兰英 . 核辐射探测 , : 北京 原子能出版社 , 1992 .
Qiu LING , Lanying GUO . Radiation detection , : Beijing Atomic Energy Press , 1992 .
0
Views
23
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621