Probabilistic safety assessment for SGTR in advanced passive nuclear power plant
is one of the important accidents in nuclear power plants
and it is significant to the safety of the nuclear power station.
Purpose:
2
In this paper
AP1000 reactor is selected as the typical advanced passive nuclear power plant to analyze the core damage consequence caused by SGTR accident
so as to find out the weak links existing in the system.
Methods:
2
The Probabilistic Safety Assessment (PSA) method in level one has been used to analyze the SGTR accident in AP1000. After the power plant accident occurs
systems
equipment and personnel respond differently
event tree analysis method is used to obtain sequence
and the systems related to this accident are analyzed by fault tree models.
Results:
2
By the Risk Spectrum software
the total Core Damage Probability (CDF) has been calculated
and the minimal cut sets
the importance measures and the sensibility of the core damage have also been analyzed respectively.
Conclusion:
2
According to a series of analysis results
the most important basic events resulting in the core damage can be obtained
and the weak link of the system can be found
which has a certain theoretical support for the further strengthening of accident prevention and mitigation of the core damage caused by the accident.
关键词
Keywords
references
W C Hu , C H Peng . Quantitative risk assessment of induced steam generator tube rupture in severe accident . Nuclear Science and Technology , 2015 . 3 49 - 54 . DOI: 10.12677/NST.2015.33008 http://doi.org/10.12677/NST.2015.33008 .
Jinquan YAN , Qinfang ZHANG , Yongping QIU , . Level 1 and 2 probabilistic safety assessment for designing a 300 MW NPP . Nuclear Techniques , 2010 . 33 ( 2 ): 87 - 91 . http://www.cnki.com.cn/Article/CJFDTOTAL-HJSU201002002.htm .
C Ye , M G Zheng , Y Wang , . Study on the long-term passive cooling extension of AP1000 reactor . Nuclear Science and Techniques , 2013 . 24 ( 4 ): 70 - 76 . DOI: 10.13538/j.1001-8042/nst.2013.04.013 http://doi.org/10.13538/j.1001-8042/nst.2013.04.013 .
Mingguang ZHENG , Cheng YE , Xu HAN . The development of nuclear power as an alternative energy . Nuclear Techniques , 2010 . 33 ( 2 ): 81 - 86 . http://www.cnki.com.cn/Article/CJFDTOTAL-HJSU201002001.htm .
CHOU Yongping, LIU Haibin, FANG Likai, et al. AP1000 self-independent standard design probabilistic safety assessment[R]. Shanghai:Shanghai Nuclear Engineering Research and Design Institute, 2011