Xinyi YIN, Ming HE, Kejun DONG, et al. Preparation of 151Sm calibration standards for AMS measurement[J]. Nuclear techniques, 2016, 39(7): 070502 DOI: 10.11889/j.0253-3219.2016.hjs.39.070502.
介绍了用于HI-13串列加速器质谱(Accelerator Mass Spectra
AMS)测量的
151
Sm实验室参考标准的研制。
151
Sm是长寿命放射性核素,自然界不存在。通过富集稳定同位素
150
Sm(n
γ)反应合成
151
Sm,并以热电离同位素质谱仪(Thermal Ionization Mass Spectrometry
TIMS)测得样品中同位素比
151
Sm/
150
Sm为3.75×10
-3
,相对不确定度为0.06%。然后加入稳定的同位素
154
Sm稀释,制得
151
Sm/
154
Sm比值分别为(9.25±0.08)×10
-7
、(8.87±0.08)×10
-8
、(8.08±0.08)×10
-9
的系列参考标准。
Background:
2
The long-lived fission product
151
Sm plays an important role in environmental science
life science
nuclear data
etc.
It is interesting to establish a high precise and sensitivity measurement method with Accelerator Mass Spectra (AMS) and develop a series of standards of
151
Sm.
Purpose:
2
The aim is to develop a series of laboratory reference standards for
151
Sm AMS measurements.
Methods:
2
The long-lived radioactive nuclide
151
Sm was produced
via
neutron capture reaction of
150
Sm by the irradiation of 52.6-mg Sm
2
O
3
(with
150
Sm enriched to 87
.34%) in the Heavy Water Research Reactor (HWRR) at China Institute of Atomic Energy (CIAE). The
151
Sm/
150
Sm ratio in the irradiated Sm
2
O
3
sample was measured with Thermal Ionization Mass Spectrometry (TIMS) at the Nuclear Power Institute of China (NPIC). This standard
151
Sm sample was then diluted with the enriched
154
Sm
2
O
3
(
154
Sm is enriched to 98.61%) to obtain three other standards.
Results:
2
The
151
Sm/
150
Sm ratio in the irradiated Sm
2
O
3
sample is 3.75×10
-3
(the relative standard deviation is 0.06%) measured with TIMS. Three standards with
151
Sm/
154
Sm ratios of (9.25±0.08)×10
-7
(8.87±0.08)×10
-8
and (8.08±0.08)×10
-9
respectively
were prepared for the calibration in AMS measurement of
151
Sm. The concentrations of Sm in standard solution (I) and diluent solution were measured using isotopic dilution mass spectrometry.
Conclusion:
2
The measurement method of TIMS for isotope ratio of
151
Sm was established. A series of standards was prepared for the calibration in AMS measurement of
151
Sm.
倪 嘉缵 . 稀土生物无机化学 , : 北京 科学出版社 , 1994 . 162 .
Jiazan NI . Bioinorganic chemistry of rare earth elements , : Beijing Science Press , 1994 . 162 .
H Q Xiao , F L Li , Z Y Zhang , . Accumulation and distribution of samarium-153 in rat brain after intraperitoneal injection . Biological Trace Element Research , 2005 . 104 ( 1 ): 33 - 40 . DOI: 10.1385/BTER:104:1:033 http://doi.org/10.1385/BTER:104:1:033 .
H Q Xiao , F L Li , Z Y Zhang , . Distribution of ytterbium-169 in rat brain after intravenous injection . Toxicology Letter , 2005 . 155 247 - 252 . DOI: 10.1016/j.toxlet.2004.09.021 http://doi.org/10.1016/j.toxlet.2004.09.021 .
C H Evans . Biochemistry of the lanthanides , : New York Plenum Press , 1990 .
M Pennick , K Demmos , S J P Damment . Absolute bioavailability and disposition of lanthanum in healthy human subjects administered lanthanum carbonate . The Journal of Clinical Pharmacology , 2006 . 46 738 - 746 . DOI: 10.1177/0091270006289846 http://doi.org/10.1177/0091270006289846 .
M Kato , J Sugihara , T Nakamura , . Electron microscopic study of the blood-brain barrier in rats with brain edema and encephalopthy due to acute hepatic failure . Gastroenterologia Japonica , 1989 . 24 ( 2 ): 135 - 142 .
J Xu , E A Ling . Studies of the ultrastructure and permeability of the blood-brain barrier in the developing corpus callosum in postnatal rat brain using electron dense tracers . Journal of Anatomy , 1994 . 184 ( 2 ): 227 - 237 .
易 健民 , 阎 建辉 , 周 宁波 . 生物样品中微量稀土元素的测定 . 精细化工中间体 , 2003 . 33 ( 3 ): 61 - 62 .
Jianmin YI , Jianhui YAN , Ningbo ZHOU . Determination of trace rare earth elements in biological samples . Fine Chemical Intermediates , 2003 . 33 ( 3 ): 61 - 62 .
R A Muller . Radioisotope dating with a cyclotron . Science , 1977 . 196 489 - 494 . DOI: 10.1126/science.196.4289.489 http://doi.org/10.1126/science.196.4289.489 .
D Elmore , F M Phillips . Accelerator mass spectrometry for measurement of long-lived radioisotopes . Science , 1987 . 236 543 - 550 . DOI: 10.1126/science.236.4801.543 http://doi.org/10.1126/science.236.4801.543 .
0
Views
21
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621