为有效实现数字射线扫描成像检测系统性能的定量分析评价,据此进行检测工艺参数的优化,对数字射线扫描成像检测系统调制传递函数(Modulation transfer function
MTF)进行了测试分析。采用刀口工具、双线型像质计、分辨率测试卡,对系统在不同焦点大小、放大倍数、运动方向的检测情况,分别进行了MTF的测试并进行了比较。结果表明,双线型像质计与分辨率测试卡的测试结果基本一致,但双线型像质计更便于对比度的定量计算;双线型像质计的对比度传递函数近似符合二次曲线,经转换得到的调制传递函数值高于刀口法的测试值,刀口法计算数值偏低的原因在于运动不平稳所带来的不利影响。分析表明,数字射线扫描成像系统性能受到多个因素的共同影响,MTF测试结果可较全面地对影响因素进行定量评价,可用于确定最佳的检测参数或找出等价的参数组合。
Background
2
Nowadays
digital radiography is widely utilized in non-destructive testing. However
some issues concerning this new technique need to be addressed properly
and some key parameters of the imaging system need to be quantified by some measurement methods.
Purpose
2
To evaluate a digital radiography system using linear detector array quantitatively and efficiently
and optimize the testing parameters accordingly
modulation transfer function (MTF) of the imaging system was calculated and analyzed. Methods: Edge tool
duplex wire image quality indicator (IQI) and resolution test card were used to measure MTF of the system under different testing parameters
which include focus size
magnification and object orientation.
Results
2
Results show that the contrast transfer function (CTF) measured by duplex IQI and resolution test card is almost identical
while signals from duplex IQI are easier to analyze quantitatively. CTF from duplex IQI is approximately a curve of second order
and the CTF can be used to transform to MTF
but the values are higher than that from edge tool
as movement during image acquisition process is unstable.
Conclusion
2
After analysis
we find that the system performance is affected by many factors together
but MTF can be used to evaluate these factors perfectly
thus to find out equivalent parameters combination or determine the optimum testing parameters.
U Ewert , K Bavendiek , J Robbins , . New compensation principles for enhanced image quality in industrial radiology with digital detector arrays . Materials Evaluation , 2010 . 68 ( 2 ): 163 - 168 .
梁 丽红 , 路 宏年 . X射线数字成像系统传递函数模型 . 北京航空航天大学学报 , 2005 . 31 ( 9 ): 1018 - 1021 .
Lihong LIANG , Hongnian LU . Transfer function model on X-ray digital radiography system . Journal of Beijing University of Aeronautics and Astronautics , 2005 . 31 ( 9 ): 1018 - 1021 .
邵 军明 , 路 宏年 , 蔡 慧 . X射线成像系统点扩展函数理论模型及其实验验证 . 光学技术 , 2005 . 31 ( 1 ): 104 - 106 .
Junming SHAO , Hongnian LU , Hui CAI . Research of X-ray imaging system point spread function in theory and experiment . Optical Technique , 2005 . 31 ( 1 ): 104 - 106 .
邵 军明 , 路 宏年 , 候 涛 . 射束有效宽度与成像系统MTF关系的研究 . 光学技术 , 2003 . 29 ( 2 ): 242 - 244 .
Junming SHAO , Hongnian LU , Tao HOU . Research of relation between X-ray beam effective width and MTF of imaging system . Optical Technique , 2003 . 29 ( 2 ): 242 - 244 .
Standard guide for radioscopy:ASTM E1000-98(2009)[S]. ASTM International, 2009. DOI: 10.1520/E1000-98R09
Shaw C C, Liu X M, Lemacks M, et al. Optimization of MTF and DQE in magnification radiography-a theoretical analysis[C]. Proceedings of SPIE (International Society for Optical Engineering), 2000, 3977:466-475
T Sakellaris , M Koutalonis , G Spyrou , . A Monte Carlo study of the influence of focal spot size, intensity distribution, breast thickness and magnification on spatial resolution of an a-Se digital mammography system using the generalized MTF . Physica Medica , 2014 . 30 286 - 295 .
K N Chandrasekharan , B P Patil , J K Ghosh . Continuous motion radiography:system evaluation using modulation transfer function . Insight , 1995 . 37 ( 2 ): 101 - 104 .
袁 永腾 , 缪 文勇 , 丁 永坤 , . ICF 流体力学不稳定性实验中调制传递函数的测量 . 强激光与粒子束 , 2009 . 21 ( 2 ): 245 - 248 .
Yongteng YUAN , Wenyong MIAO , Yongkun DING , . Mdulation transfer function measurement in ICF hydrodynamic instability experiments . High Power Laser and Particle Beams , 2009 . 21 ( 2 ): 245 - 248 .
刘 海宽 , 张 建 , 王 昌元 , . 用星形测试卡测试屏-片系统MTF的实验探讨与应用 . 中国医学物理学杂志 , 2006 . 23 ( 4 ): 250 - 252 .
Haikuan LIU , Jian ZHANG , Changyuan WANG , . Testing screen/film system MTF using star testing card . Chinese Journal of Medical Physics , 2006 . 23 ( 4 ): 250 - 252 .
V Kaftandjian , Y M Zhu , G Roziere , . A comparison of the ball, wire, edge, and bar/space pattern techniques for modulation transfer function measurements of linear X-ray detectors . Journal of X-ray Science and Technology , 1996 . 6 205 - 221 .
王 雨 , 韩 松柏 , 贺 林峰 , . 中子照相图像分辨率计算方法 . 核技术 , 2012 . 35 ( 4 ): 275 - 280 .
Yu WANG , Songbai HAN , Linfeng HE , . Calculation methods for neutron radiography spatial resolution . Nuclear Techniques , 2012 . 35 ( 4 ): 275 - 280 .
L E Nickoloff , E Donnelly , L Eve , . Mammographic resolution:influence of focal spot intensity distribution and geometry . Medical Physics , 1990 . 17 ( 3 ): 436 - 447 .
孙 朝明 , 汤 光平 , 李 强 , . X射线源焦点尺寸的测试与对比分析 . 核技术 , 2015 . 38 ( 11 ): 110202 DOI: 10.11889/j.0253-3219.2015.hjs.38.110202 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.110202 .
Chaoming SUN , Guangping TANG , Qiang LI , . Comparative analysis and measurement of focus spot for X-ray source . Nuclear Techniques , 2015 . 38 ( 11 ): 110202 DOI: 10.11889/j.0253-3219.2015.hjs.38.110202 http://doi.org/10.11889/j.0253-3219.2015.hjs.38.110202 .
Standard practice for manufacturing characterization of digital detector arrays:ASTM E2597-14[S]. ASTM International, 2014. DOI:10.1520/E2597_E2597M-14 http://dx.doi.org/DOI:10.1520/E2597_E2597M-14
Pitcher D C. Quantitative metrics to evaluate image quality for computed radiographic images[D]. Florida:University of Florida, 2004
江 孝国 , 谭 肇 , 李 泽仁 , . X光面光源的尺寸对系统线扩展函数的影响 . 强激光与粒子束 , 2004 . 16 ( 3 ): 296 - 300 .
Xiaoguo JIANG , Zhao TAN , Zeren LI , . Influence of X-ray area-source on LSF in radiography system . High Power Laser and Particle Beams , 2004 . 16 ( 3 ): 296 - 300 .
0
Views
22
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621