Junqin LI, Ying ZOU, Zhenhua CHEN, et al. Ionization chamber based on multichannel plate and its application on synchrotron radiation[J]. Nuclear techniques, 2016, 39(5): 050101
DOI:
Junqin LI, Ying ZOU, Zhenhua CHEN, et al. Ionization chamber based on multichannel plate and its application on synchrotron radiation[J]. Nuclear techniques, 2016, 39(5): 050101 DOI: 10.11889/j.0253-3219.2016.hjs.39.050101.
Ionization chamber based on multichannel plate and its application on synchrotron radiation
The measurement of energy resolution is an essential task for commissioning a beamline in synchrotron radiation facility. The ionization chamber plays an important role in the evaluation of energy resolution. The conventional type based on electrode probe has the disadvantage of a low detection upper limit for energy resolution due to collision broadening on peak profiles by high working pressure(up to 1.33Pa).
Purpose:
2
To improve the upper limit of resolution measurement
we aim to set up and deploy the ionization chamber based on multichannel plate(MCP) in China
including vacuum system
gas inlet system
detection system and data acquisition and processing system.
Methods:
2
Taking advantage of high amplification of a MCP detector
gas ionization absorption spectra can be measured under much low working pressure(1.33×10
-4
Pa). By analyzing the width of absorption peak
the instrument broadening caused by a beam line can be obtained.
Results:
2
An ionization chamber based on MCP can achieve higher upper limit than those based on electrode probe in evaluating energy resolution.
Conclusion:
2
A MCP ionization chamber provides an important diagnosis for energy resolution in commissioning high performance beamlines.
XUE Chaofan . Study of evaluating the energy resolution of the soft X-ray spectromicroscopy beamline at SSRF . Shanghai:Shanghai Institute of Applied Physics, Chinese Academy of Sciences , 2011 .
XUE Chaofan , WANG Yong , WU Yanqing , . Effect of gas pressure on energy resolution of a soft X-ray beamline . Nuclear Techniques , 2011 . 34 ( 8 ): 561 - 564 .
Xue L , Reininger R , Wu Y Q , . Design of an ultrahigh-energy-resolution and wide-energy-range soft X-ray beamline . Journal of Synchrotron Radiation , 2014 . 21 ( 1 ): 273 - 279 .
Domke M , Mandel T , Puschmann A , . Performance of the high-resolution SX700/Ⅱ monochromator . Review of Scientific Instruments , 1992 . 63 ( 1 ): 80 - 89 .
Hu Y F , Zuin L , Wright G , . Commissioning and performance of the variable line spacing plane grating monochromator beamline at the Canadian Light Source . Review of Scientific Instruments , 2007 . 78 ( 8 ): 083109 .