Analyses and tests of cooling capability of EAST-NBI deflection magnet coils
Background: The deflection magnet is one of the key components of the neutral beam injector
it is installed in the neutral beam injector vacuum chamber. While the neutral beam injector works
the heat generated by current running through exciting coils of deflection magnet must be taken away by the cooling water simultaneously. Purpose: In order to meet the requirements of the developing nuclear fusion researches
the neutral beam injector must work steadily
providing neutral beam of high energy
high power continuously. The cooling abilities of the deflection magnets must be enhanced. Methods: The water cooling structure of excitation coils of the original deflection magnet was optimized by adding a pair of water taps in each primary coil
and the tests were made to check the cooling capbilities of the improved exciting coils. Results: When the neutral beam injector runs at the state of long pulse
improved water cooling structures take away the heat generated by the exciting coils timely. The improvement of the cooling abilities of the coils was successful. Conclusion: The temperature difference between the inlet and outlet of the cooling water pipe is about 21 oC
and the surface temperature of deflection magnet coil is about 45 oC. Abstract