XU Jiaqiang, XIA Xiaobin, SHENG Yinxiangzi, et al. Dose calculation and measurement for bremsstrahlung at BL18U beamline of SSRF[J]. Nuclear techniques, 2014, 37(7): 070101
DOI:
XU Jiaqiang, XIA Xiaobin, SHENG Yinxiangzi, et al. Dose calculation and measurement for bremsstrahlung at BL18U beamline of SSRF[J]. Nuclear techniques, 2014, 37(7): 070101 DOI: 10.11889/j.0253-3219.2014.hjs.37.070101.
Dose calculation and measurement for bremsstrahlung at BL18U beamline of SSRF封面论文
Background: Gas bremsstrahlung is one of the most important radiation sources that needs to be taken into consideration for shielding design of beamlines at the third generation synchrotron radiation light source. Shanghai Synchrotron Radiation Facility (SSRF) is one of the third generation synchrotron radiation light source in the world. The Protein Micro-crystallography Beamline (BL18U) is one of the commissioning beamlines and is a representative insertion device beamline at SSRF. Purpose: Estimation of radiation dose induced by scattering bremsstrahlung and photoneutrons at BL18U. Methods: Dose rate distribution induced by scattering bremsstrahlung and photoneutrons at BL18U are performed by Monte Carlo simulation code FLUKA. The radiation dose was analyzed with the variation of slits size
beam current at storage ring and the vacuum. Dose rate of photons and photoneutrons at the outside of the optical enclosure of BL18U were measured by using high sensitivity photon and neutron monitors. Results: The measurement results show that the reliability of the simulation. Conclusion: The simulation and measurement methods presented in this study can be applied to evaluate the dose rate level of other beamline stations at SSRF
and provide references to the shielding design for the following beamlines at SSRF in the near future. Abstract