Detection efficiency simulation and measurement of 6LiI/natLiI scintillation detector
更新时间:2021-03-03
    • Detection efficiency simulation and measurement of 6LiI/natLiI scintillation detector

    • NUCLEAR TECHNIQUES   Vol. 37, Issue 4, Article number: 040201(2014)
    • DOI:10.11889/j.0253-3219.2014.hjs.37.040201    

      CLC:
    • Published:11 April 2014

    移动端阅览

  • DU Long, CHANG Le, WANG Yuting, et al. Detection efficiency simulation and measurement of 6LiI/natLiI scintillation detector[J]. Nuclear techniques, 2014, 37(4): 040201 DOI: 10.11889/j.0253-3219.2014.hjs.37.040201.

  •  
  •  