HE Xiaoye, WANG Wei, WANG Peng, et al. Alignment control network scheme design and measurement of HLS upgrade[J]. Nuclear techniques, 2013, 36(10): 100102
HE Xiaoye, WANG Wei, WANG Peng, et al. Alignment control network scheme design and measurement of HLS upgrade[J]. Nuclear techniques, 2013, 36(10): 100102 DOI: 10.11889/j.0253-3219.2013.hjs.36.100102.
Alignment control network scheme design and measurement of HLS upgrade
Background: In order to open up the application field and improve the source
the Hefei Light Source(HLS) is taken a major upgrade. Purpose: The paper mainly introduces the way of building and measuring of alignment control network during the HLS upgrade. Methods: The global horizontal control network points’ data are measured by total station. All control network points’ 3D-measurement data are obtained by laser tracker and elevation data are got by N3 Level. The function of Unified Spatial Metrology Network(USMN) of SA software is used to make a three dimensional adjustment combining data from different devices. The concept of measurement uncertainty is used to describe the measurement quality of network points. In order to check the correctness of the adjustment result
the software of MAA was employed to make three-dimensional adjustment as well as plane adjustment done by SURVEY adding elevation adjustment by NASEW2003. Results: Through the actual measurement and data processing
the accuracy of actual measurement is 0.09 mm
better than the designed accuracy of 0.15 mm. Compared with the results adjustment by different software
the result of SA is demonstrated to be reliable. Conclusion: The result demonstrates that the designed scheme of alignment control network of HLS upgrade is reasonable and feasible.