Determination of iodine in 20 Chinese biological standard reference materials by ENAA
The epithermal neutron activation analysis (ENAA) using BN and BN+Cd as thermal neutron shielding materials was used to determine the contents of iodine in 20 Chinese biological standard reference materials (SRMs). The analytical precision
expressed by the relative standard deviation
is 2%-6% and 8%-12% for solid samples with iodine level of more than 100ng/g and 20-100ng/g
respectively
and 12%-18% for liquid samples with iodine level of less than 100ng/g. The detection limits of iodine in our experimental condition vary between 10-30ng/g
55-95ng/g and 25-68ng/g for BN-shielding in inner irradiation site
Cd-shielding and BN+Cd shielding in outer irradiation site
respectively. Furthermore
four international biological SRMs were determined
and the experimental results agreed well with the certified or literature values.