浏览全部资源
扫码关注微信
上海市药品检验所
Published:01 May 1994
移动端阅览
[1]黄天森,吴卫国,蒋红珠.~(99m)Tc-MDP放化纯测定法的改进[J].核技术,1994(05):301-303.
Improvement on the method for determining radiochemical purity of  ̄(99m)Tc-MDP[J]. Nuclear techniques, 1994, (5).
采用纸层析方法,以0.9%氯化钠(Ⅰ)和85%甲醇(Ⅱ)为两个展开剂系统,测定了99mTc、99mTc-胶体和99mTc-MDP的Rf值。其Rf值在Ⅰ中分别为0.68—0.76、0和1.0;在Ⅱ中分别为0.6-0.7、0和0.结果表明,用Ⅰ可将99mTc-胶体与99mTc和99mTc-MDP分离;用Ⅱ可将99mTc与99mTc-胶体和99mTc-MDP分离.条件试验的结果表明,在两个系统中选择新华一号滤纸为载体,并在Ⅰ中采用氮压下展层的方法,可用以测定99mTc-MDP的放化纯,其方法简便、可行、有效。
By paper chromatagraphy method
taking 0.9% Nacl(System Ⅰ) and 85%methanol (System Ⅱ) as two developing solvent systems
the Rf values of 99mTc
99mTc- colloid and 99mTc- MDP were determined.They are respectively 0.68-0.76
0 and 1.0 in System Ⅰ; 0.6-0.7
0 and 0 in System Ⅱ.This result indicates 99mTc-colloid can be separated from 99mTc and 99mTc-MDP with SystemⅠ;99mTc separated from 99mTc-colloid and 99mTc-MDP with System Ⅱ. The result indicates the radiochemical purity of 99mTc-MDP can be determined by the two developingsolvent systems and developing under nitrogen pressure in SystemⅠ.The method is convenient
feasible and effective.