HU Chunming DAI Junlong SHEN Wende LIU Xiankun. Cold neutron source to be established at a research reactor[J]. Nuclear techniques, 2005, (3): 209-212.
HU Chunming DAI Junlong SHEN Wende LIU Xiankun. Cold neutron source to be established at a research reactor[J]. Nuclear techniques, 2005, (3): 209-212.DOI:
Cold neutron source to be established at a research reactor
a set of Neutron Scattering Experimental Facility (NSEF) will be installed at a new research reactor. A cold neutron source (CNS)
one of the most important components of NSEF
is a mono-phase liquid hydrogen moderator of vertical thermosiphon type. Nice working capacity and safety are main advantages of the CNS with a sub-cooled liquid hydrogen thermosiphon. Cooling helium from refrigerator removes the total heat load from the CNS in the heat exchanger. In the paper
an introduction of the principle and arrangement of the CNS is given
and technical parameters of the CNS are described in detail.
Experimental research on the formation and controlling of molten salt frozen-wall
Numerical simulation of the ablation process of the nuclear pressure vessel heated by core melt
Neutronics calculation of a reactor cold neutron source
Measurement and analysis of annealing factor and typical dc electronic parameters for SiGe HBT irradiated by neutrons and gamma rays in a pulsed reactor
A novel design method for nuclear fusion reactor
Related Author
SUN Bo
SHE Changfeng
DOU Qiang
LONG Dewu
LI Qingnuan
WU Guozhong
ZHOU Jinhao
ZHANG Xiaoying
Related Institution
Key Laboratory of Nuclear Radiation and Nuclear Technology, Chinese Academy of Sciences
Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Jiading Campus
School of Electricity, South China University of Technology