REN Xiang GE Liangquan ZHANG Qingxian YU Xinhua LIANG Wenjun. A method to correct effect of drilling fluid on in situ X-ray fluorescence logging[J]. Nuclear techniques, 2009, 32(10): 756-759.
REN Xiang GE Liangquan ZHANG Qingxian YU Xinhua LIANG Wenjun. A method to correct effect of drilling fluid on in situ X-ray fluorescence logging[J]. Nuclear techniques, 2009, 32(10): 756-759.DOI:
A method to correct effect of drilling fluid on in situ X-ray fluorescence logging
the variation of thickness of drilling fluid between the detector and wall affects the measurement result.A new correction method is established by acquiring the characteristic parameter of the XRF spectrum.The experimental results show that it is a simple
rapid
and practical correction method to samples of high concentration.After correction
deviation of peak area of the characteristics X-rays is 5% less than those measured without interference from the drilling fluid.