[1]傅成栋,汪晓莲,李澄,许咨宗.充Xe多丝室中Xe的KX射线对成像性能影响的MC模拟[J].核技术,2002(03):183-188.
FU Chengdong WANG Xiaolian LI Cheng XU Zizong. MC simulation study of X-ray image in a high pressure xenon gas chamber[J]. Nuclear techniques, 2002, (3): 183-188.
对不同能量 (2 0— 10 0keV)的X射线在充 3个大气压Xe的多丝室中与Xe原子相互作用的过程进行了蒙特卡罗模拟研究
讨论康普顿散射和Xe的特征X射线对高气压丝室的定位性能的影响
并通过对低密度试模成像的模拟
观察KX射线在高气压丝室中引起的图象畸变。同时提出了一种对特征KX射线和散射射线引起的图象畸变的修正方法
The multi- wire proportional counter (MWPC) has been intensively applied to the image formation measurement in high energy physics. The interaction of various energy X-rays (20—100keV) with Xe atoms in a MWPC filled with high pressure Xe gas was studied by Monte Carlo simulation. The influence of scattered X-ray and Xenon’s KX-ray on the accuracy of position determination with the counter was investigated. The distortion of image coused by scattered and KX-rays was studied by low density virtual model simulation. A method was proposed to correct the image distortion.