浏览全部资源
扫码关注微信
1. 中国科学院等离子体物理研究所
2. 华东理工大学理学院
Published:01 December 2007
移动端阅览
[1]张国平,胡立群,张先梅,黄娟.诊断中性束在合肥托卡马克等离子体中的衰减计算[J].核技术,2007(12):1011-1015.
ZHANG Guoping HU Liqun ZHANG Xianmei HUANG Juan. Calculation on attenuation of diagnostic neutral beam in Hefei tokamak plasma[J]. Nuclear techniques, 2007, (12): 1011-1015.
考虑诊断中性束在HT-7等离子体中的电离
复合和电荷交换
对不同靶等离子体的等离子体温度、密度和杂质含量
计算了中性束在等离子体中的衰减。分析结果表明
等离子体的密度对中性束的衰减影响较大
而温度的变化对中性束衰减影响较小。当增大时
中性束衰减率随等离子体密度显著增大;当中性束的能量增大时
中性束也衰减较甚。含杂质中性束的衰减率也增大。最后
根据诊断中性束在EAST托卡马克中等离子体衰减的计算结果
给出了EAST托卡马克中等离子体所要求的诊断中性束参数。
In this work
attenuation of the injected diagnostic neutral beam in different electron temperatures
electron densities
and impurity concentrations of the target plasma in HT-7 tokamak was calculated by considering effects of the three basic atomic processes
i.e. ionization
recombination and charge-exchange. The results show that the attenuation depends strongly on the plasma density and beam energy
but the plasma temperature has less effect. The attenuation of the diagnostic neutral beam in the EAST plasma has been estimated based on the same principle
and the required parameters for the EAST diagnostic neutral beam are given as well.
0
Views
33
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621