ZHANG Qiang1 DENG Yuequan1 GU Yongmei1 DONG Faqin1 XU Guangliang1 HE Dengliang2 1. Study on influencing factors in radon measurement of building materials and its application in research of radon prevention materials[J]. Nuclear techniques, 2007, (3): 236-240.
ZHANG Qiang1 DENG Yuequan1 GU Yongmei1 DONG Faqin1 XU Guangliang1 HE Dengliang2 1. Study on influencing factors in radon measurement of building materials and its application in research of radon prevention materials[J]. Nuclear techniques, 2007, (3): 236-240.DOI:
Study on influencing factors in radon measurement of building materials and its application in research of radon prevention materials
The grain size of building materials products has a great influence on the radon release level.The release amount of radon is the greatest when the grain size is 5 mm
and the release levels will reduce for any other dimensions.Temperature has also important effect on the release of radon from building materials products.The concentration of radon will double when temperature raises 5℃ at 20℃ or higher
especially
when temperature is higher than 25℃
the concentration rises even more rapidly.The activation energy Ea of radon release for the fly ash samples is measured to be 77194.19 J.mol-1
and the factor A is 4.54×1015 s-1.The concentration of radon increases gradually with time
the release and decay of radon will reach equilibrium 36 h later
and the relative standard deviation of the fluctuating value of radon concentration is 2.1% at that moment.The relative standard deviation of the rate of preventing radon for the radon prevention coating is 3.8%.The results are reliable when the method is used in the research of radon prevention mortar and putty.